Black V anti-mors
EN
Black V anti-spill/anti-verschütt/anti-gaspillage
Calibration
Calibrating the Black V can be done using the following steps, depending on your fee-
ding system:
1.
Go to the calibration menu of your corresponding feeding system. If necessary,
read the corresponding manual or consult your dealer. In order to access the
calibration menu of DeLaval VMS and Alpro feed station, the adjacent table can
be used.
In order to correctly measure and set the dispensed volume of feed, use the following
steps:
2.
Place a bucket beneath the dispenser to weigh the feed.
3.
Keep the test-tag of the corresponding feed type in front of the tag reader.
Feed will be dispensed during 1 minute.
4.
Afterwards, weigh the collected amount of feed, and make a note of this.
5.
Repeat steps 2 and 3 twice. This means that in total, three measurements have
been done.
6.
Calculate the average measured volume, by dividing the total volume by 3.
7.
Set this value in the feed computer or VMS software for the corresponding feed
type.
Repeat these calibration steps every month, as well as after refilling the storage, and
after changing the feed type.
Important! The Black V is exclusively intended for cylindrically
shaped concentrate feed with a diameter of Ø4 to Ø8 mm. The man-
ufacturer cannot guarantee proper functioning when using other
feed types.
Warning! The Black V
’
s motor will start as soon as it is being actua-
ted by the control unit. One will not notice it starting beforehand.
Maintenance
1.
When maintenance has to be done on the product and it is connected to a con-
trol unit, please prevent it from starting unexpectedly. Ensure the installation is
completely voltage-free. To do this, disconnect the power supply from the con-
trol unit.
2.
It is recommended to have repairs and maintenance done by a specialist.
3.
Never open the casing while the Black V is still operational. This with regard to
the danger of electric shocks or becoming trapped in the feeder auger.
4.
The user/owner of the Black V is expected to follow the advice and guidelines
of the manual, in order to keep everybody safe. If these requirements are not
fulfilled, the manufacturer cannot be held accountable in any way for personal
injury or damage to or caused by the product, and this will be solely the respon-
sibility of the user/owner.
Warning! When changes are being installed/mounted in the Black V,
make sure to shut down the power of the Black V, to prevent acci-
dents.
DeLaval VMS:
VMS menu ↓
Station ↓
Maintenance ↓
Calibrate feed station
DeLaval Alpro feed station:
Main menu ↓
Settings(4) ↓
Feed station(1) ↓
Calibration data(3)
Accessing DeLaval calibration menu
Computer (Delpro software):
Unit ↓
Select VMS ↓
Feeding; Stop feeding, as soon as
this number of teats is still being
milked→ set at 3.
Setting DeLaval VMS menu