background image

 

2 - 17 

Hanskamp AgroTech B.V. (the Netherlands) 

www.hanskamp.nl/en 

 

Black V anti-mors 

EN 

Black V anti-spill/anti-verschütt/anti-gaspillage 

Preface 

 

Manual Contents 

This manual contains the information necessary for the correct installation and operation 
of a Hanskamp Black V.  Study and understand this information thoroughly before config-
uration of the Black V. Failure to do so could result in damage to equipment. Please con-
sult your milking equipment dealer if you do not understand the information in this man-
ual, or if you need additional information. 
All information in this manual has been compiled with care. Hanskamp shall not be liable 
for errors or faults in this manual. The recommendations are meant to serve as guide-
lines. All instructions, pictures and specifications in this manual are based on the latest 
information that was available at the time of publication. Your Black V may comprise 
improvements, features or options that are not covered in this manual. 
 

Applicability 

The table below shows the type numbers of the Black V for which this manual is  
applicable. 
 
Model designation 

 
 
 
 

Both model types function identically. The orientation of the electromotor is however 
different, to ensure the Black V can be mounted correctly (fig. 1). 
 

Contact number Local Service Provider 

We  suggest  you  write  the  name,  address  and  telephone  number  of  your  local  service 
provider contact in the table below. This makes sure you can easily find the information. 

 

Model 

Type number 

Fits in 

002-672-010 

Feedstation (DeLaval FSC 40&400

Black V anti-spill  

002-672-020 

VMS  

Name 

 

Address 

 

Telephone number 

 

E-mail address 

 

002-267-010 

002-267-020 

Lateral view Black V 

Summary of Contents for 002-672-010

Page 1: ...1 Translation of original manual According to Annex 1 chapter 1 7 4 Machine Guideline 2006 42 EC Doetinchem The Netherlands www hanskamp nl en in feed station 002 672 010 in VMS 002 672 020 Anti mors...

Page 2: ...de lines All instructions pictures and specifications in this manual are based on the latest information that was available at the time of publication Your Black V may comprise improvements features o...

Page 3: ...underneath the concentrate supply line The motor actuates an auger which dispenses the concentrate in a portionwise manner This is accomplished by a dosing disc After dispensing a portion the disc wil...

Page 4: ...E operation and maintenance of your Black V YOU must make sure that you and anyone else who is going to operate maintain or work in the vi cinity of the Black V knows all the related SAFETY informatio...

Page 5: ...upply for the Black V Make sure the electrical grounding of the electrical system and all parts of the Black V meet the local rules and regulations Replace any damaged electrical lines conduits switch...

Page 6: ...Switch off the electrical power supply by taking plug out of the power point and secure the plug before you clean or do maintenance on the Black V Wear protective clothing and safety goggles when you...

Page 7: ...fferent parts that may fall out of the box Always keep the box stable with the opening on top Warning Watch out for damages or lose ends that could suffer injuries Safety stickers The user and install...

Page 8: ...lockwise For connecting the Black V to DeLaval Feed 2 Alpro Delpro feed stations a wiring scheme is shown in annex 3 For connecting to other con trol units please refer to the corresponding manual Imp...

Page 9: ...man ufacturer cannot guarantee proper functioning when using other feed types Warning The Black V s motor will start as soon as it is being actua ted by the control unit One will not notice it startin...

Page 10: ...ever in the event of faults Hanskamp cannot be held responsible for consequential damage Nr Release date Chapter s Comments 1 1 06 2016 First release 1 2 07 2016 Insertion of dimensions Black V models...

Page 11: ...the following directive s Machine Directive 2006 42 EC Annex I art 1 1 2 1 1 3 1 1 5 1 1 6 1 2 6 1 3 1 1 3 7 1 3 8 2 1 4 1 1 5 1 1 5 5 1 5 6 1 5 7 1 5 8 en 1 5 9 EMC Directive 2004 108 EG Annex I art...

Page 12: ...B V the Netherlands www hanskamp nl en Black V anti mors EN Black V anti spill anti versch tt anti gaspillage Annex 1 Dimensions Black V in mm Fits in VMS Art no 002 672 020 Fits in out of parlour fe...

Page 13: ...l data of the RIM motor Technical data Supply voltage 12 24V AC DC Idle current 350 mA Nominal current 360 mA Maximum current 440 mA Capacitor 22 F Electromotor 28 Rpm Capacity 500 1200 g min Storage...

Page 14: ...en Black V anti mors EN Black V anti spill anti versch tt anti gaspillage Annex 3 Connection Scheme for DeLaval Feed2 Alpro Delpro StationController Available feed type slot Available feed type slot P...

Page 15: ...mors EN Black V anti spill anti versch tt anti gaspillage Annex 4 Individual parts For maintenance purposes or any other reason it is possible to re order individual parts from your supplier When doi...

Page 16: ...Tap bolt M6x16 DIN 931 3 001 284 000 Self drilling screw3 5x9 5mm 4 001 366 000 Spring washer m6 A2 DIN 137B 3 001 774 000 Washer M8 DIN 9021 A2 1 001 784 000 PP T piece 45 110 mm black 1 001 808 000...

Page 17: ...r pipe 90 mm stainless steel 2 001 845 000 Mounting bracket 3 mm 1 001 846 000 Tube mounting clamb M8 45 mm 2 001 849 000 Outfall Black V 1 Article number Description Aantal Fits in system 011 125 000...

Page 18: ...ds www hanskamp nl en Black V anti mors EN Black V anti spill anti versch tt anti gaspillage Hanskamp AgroTech B V Broekstraat 17 7009 ZB Doetinchem The Netherlands Tel 31 0 314 393 797 Fax 31 0 314 3...

Reviews: