Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Regulator filter dirty
- Clean filters
- Shower filter seal dirty
- Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
- Backflow preventers dirty or
leaking
- Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
- Thermostat has not been adjusted
- Adjust thermostat
- Hot water temperature too low
- Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible - Temperature regulator dirty or
calcified
- Clean temperature regulator,
exchange if necessary
- For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180º rotation
- Install function block turned through
180º
Safety stop button not operating
- Spring defective
- Button calcified
- Clean spring and/or button,
exchange if necessary
Diverter stiff
- Cartridge defective
- Exchange cartridge
Diverter leaking
- Dirt or sedimentation on valve seat. - Clean valve seat or exchange
diverter
English
Assembly see page 60
Summary of Contents for Montreux 16820 Series
Page 25: ...42 C 65 C 180 180 60 25...
Page 27: ...42 65 180 60 27...
Page 43: ...42 C 65 C 180 180 60 43...
Page 55: ...42 C 65 C 180 180 60 55...
Page 58: ...42 65 180 180 58...
Page 60: ...2 1 1 2 3 Starck StarckX Montreux Carlton CitterioM Steel Terrano Uno Citterio 1 2 4 3 5 6 60...
Page 61: ...1 2 3 4 Starck StarckX Montreux Carlton CitterioM Steel Terrano Uno Citterio 7 8 61...
Page 62: ...Silikon 2 1 1 2 3 Massaud Bouroullec 1 2 4 3 5 6 62...
Page 63: ...Massaud Bouroullec 3 2 1 7 8 63...
Page 64: ...z B 42 C for example 42 C 4 3 1 2 2 1 6 1 2 5 64...
Page 65: ...1 3 2 65...
Page 66: ...2 3 4 1 1 2 3 4 6 5 1 2 1 2 A A 66...
Page 67: ...8 9 10 7 1 2 1 2 3 4 5 11 67...