Hansen PXV Series Specifications, Applications, Service Instructions & Parts Download Page 12

12

P249 
OCT 2013

CAUTION

Hansen valves are only for refrigeration systems. These 
instructions must be completely read and understood 
before selecting, using or servicing Hansen valves. 
Only knowledgeable, trained refrigeration mechanics 
should install, operate, or service these valves. Stated 
temperature and pressure limits should not be exceeded.  
Bonnets, solenoid tubes, etc. should not be removed 
from valves unless system has been evacuated to zero 
pressure. you must also see Safety Precautions in the 
current List Price Bulletin and Safety Precautions Sheet 
supplied with the product. escaping refrigerant might 
cause personal injury, particularly to the eyes and lungs.

WARRANTy

All Hansen products, except electronics, are guaranteed 

against defective materials or workmanship for one 
year F.O.B. factory. electronics are guaranteed against 
defective materials or workmanship for 90 days F.O.B. 
factory. No consequential damages or field labor is 
included.

PXVW VALVe SeAT

Before opening the valve for service, be sure it is isolated 
from the system and all refrigerant is removed. Carefully 
read and understand the safety precautions.

If you have additional questions or concerns please 
feel free to contact us.
1.  Disconnect electrical power from the coil.

2.  Always be careful when loosening the bonnet 

assembly to be sure no residual pressure exists.

3.  Remove the bonnet slowly by unscrewing 

counterclockwise.

4.  Once bonnet has been removed, proceed and 

remove the spring and then piston.

5.  Next use the Seat Removal Tool to extract the 

seat. (Included with Piston/Seat kit # 70-1129)

6.  Using an extension bar size ¼” x 6” long with a 

drive ratchet, attach the seat removal tool with 
the two lugs on the end.

7.  Remove seat by turning counterclockwise.

8.  Once the seat is loose, withdraw the tool.
9.  Reverse the seat removal tool and use the  

o-ring end.

10.  Press the tool with the o-ring end into the seat to 

pull out the seat.

Inspect Parts

1. Look for dirt and debris

2. Look for cuts or cracks on seat o-ring
3. Inspect capacity stem for erosion

4. Clean, repair, and replace parts (if necessary)

Reassembly Instructions

1.  Reinstall or replace parts as necessary

2.  gasket kit # 70-1125
3.  Bonnet Cartridge kit #70-0703

4.  Piston/Seat kit #70-1129

5.  Lightly lubricate new O-rings 
6.  Tighten seat ring using 8ft-lbs torque and reassemble 

bonnet cartridge using 75ft-lbs torque

ORDeRINg INFORMATION

CAT 

NO

CONNeCTION 

STyLe & SIzeS

FPT, SW, WN

ODS

STD

ALSO

STD

ALSO

PXV5

½˝ FPT

½˝ SW

PXV15

½˝ FPT

½˝ SW

PXVW60

½˝  

SW

¾˝ SW

½˝, ¾˝, 1˝ BW

1-1/8˝  

ODS

5/8˝, 7/8˝ 

ODS

CONTROLLeRS

CATALOg NUMbeR

APPLICATION

PXVC-DX

DX Control – 4-20 mA Input

PXVC-PT

DX Control – Temp/Pressure Input

PXVC-L

Level Control – 4-20 mA Input

PXVC-T

Temp. Control – NTC 10k Input

Contact factory for Controller details.

OPTIONAL beACON PILOT LIghTS

CATALOg NUMbeR

DeSCRIPTION

70-1100

Red Pilot Light Kit

70-1101

Amber Pilot Light Kit

70-1103

green Pilot Light Kit

TO ORDeR:

  Specify type, connection style and size: 

½˝ SW standard, FPT or WN available. Unless otherwise 

specified standard coil with ½˝ fitting for conduit will 

be supplied with pilot valve.  Voltages available include 

24V, 120V, and 240VAC. Also available, DIN plug coil for 
grounded cord connection.

Hansen Technologies Corporation
400 Quadrangle Drive, Suite F
Bolingbrook, Illinois 60440 USA
Tel: 630.325.1565  Fax: 630.325.1572  Toll: 866.4HANSEN  
Email: [email protected]  Web: www.hantech.com

USA  ∙  Asia   ∙  Europe  ∙  India  ∙  Latin  America  ∙  Middle East

© 2013 Hansen Technologies Corporation

Summary of Contents for PXV Series

Page 1: ...ooded heat exchangers to minimize fluctuations in liquid level and evaporator pressures and for liquid injection for compressor oil cooling key FEATURES PXV5 PXV15 drop in replacement valve for Sporla...

Page 2: ...und the valve bonnet and upper body while welding Socket weld fitting and valve codes require that the pipe be inserted until bottomed against the stop then backed out approximately 1 16 1 5 mm before...

Page 3: ...ON VALVE PRESSURE TRANSDUCER 10 00 2 00 POSITION PXV PXVC PT CONTROLLER INSULATION TEMPERATURE SENSOR AT 4 OR 8 O CLOCK POSITION PIPE TEMPERATURE SENSOR TO PROTECTED SUCTION DX EVAPORATOR EXPANSION VA...

Page 4: ...ler Application Figure 3 EXPANSION VALVE SURGE VESSEL PXV OR PXVW PULSE WIDTH OR TECHNI LEVEL VLT VARI LEVEL WITH MOD420 CUSTOMER SUPPLIED HANSEN FOR LIQUID LEVEL PXVC L CONTROLLER OPERATION Liquid in...

Page 5: ...VW Typical Liquid injection cooling for screw compressor application Figure 4 For systems using the PXVW valve the integral hand expansion stem capacity must be adjusted to match the capacity of the e...

Page 6: ...6 P249 OCT 2013 tYPICAL wiring diagrams DX Evaporator Control PXVC PT Using Separate Pressure Transducer and Temperature Sensor Figure 5...

Page 7: ...7 P249 OCT 2013 tYPICAL wiring diagrams DX Evaporator Control PXVC DX Using Hansen HPT 4 20 mA or Customer Supplied 4 20 mA Superheat Input Figure 6...

Page 8: ...8 P249 OCT 2013 tYPICAL wiring diagrams Temperature control Figure 7...

Page 9: ...9 P249 OCT 2013 tYPICAL wiring diagrams Liquid level control Figure 8...

Page 10: ...er Kit Above kit consists of Long life Plunger Solenoid Tube Solenoid Tube O Ring Tube Screws Coil Knob PXV Gasket Kit Above kit consists of Solenoid Tube O Ring Strainer Cap O Ring Flange Gasket Stra...

Page 11: ...Washer Packing Nut Seat O Ring PXVW Stem Kit Above kit consists of Capacity Adjustment Stem Gasket Kit Bonnet Cartridge Kit Above kit consists of Cartridge Assembly PXVW Piston Seat Kit Above kit con...

Page 12: ...ng with a drive ratchet attach the seat removal tool with the two lugs on the end 7 Remove seat by turning counterclockwise 8 Once the seat is loose withdraw the tool 9 Reverse the seat removal tool a...

Reviews: