Hansen PXV Series Specifications, Applications, Service Instructions & Parts Download Page 10

10

P249 
OCT 2013

PXV INSTALLATION DIMeNSIONS

INCHeS (MILLIMeTeRS)

PXV PARTS LIST

8

5

1

2

6

7

10

9

4

3

11

12a 12b

13

*

ITeM

DeSCRIPTION

qTy

PART NO.

1a

1b

1c

1d

2

5

6

7

8

2

7

4

3

10

4

9

11

12a

12b

13a

13b

Coil kit(115V) 1/2˝ Fit w/ Leads

Coil kit(208/230V) 1/2˝Fit w/ Lds

Coil kit (24V) 1/2˝ Fit w/ Leads

Coil kit (Other Voltages)

    Above kits consist of:

Bare Coil, 115V 50/60HZ w/ Leads

Bare Coil, 208/230V 50/60HZ w/ Lds

Bare Coil, 24V 50/60HZ w/ Leads

Other Voltage Coils

Coil Knob

PXV Solenoid Tube/Plunger kit

    Above kit consists of:

Long life Plunger

Solenoid Tube

Solenoid Tube O-Ring

Tube Screws

Coil Knob

PXV gasket kit

    Above kit consists of:

Solenoid Tube O-Ring

Strainer Cap O-Ring

Flange gasket

Strainer Screen kit

    Above kit consists of:

Screen Assembly, 100 mesh

Strainer Cap O-Ring

Strainer Cap

PXV Body

expansion Orifice Plug, 5 Ton(3/64˝ )

expansion Orifice Plug, 15 Ton (5/64˝ )

1/2˝ FPT Flange

1/2˝ SW Flange

1

1

1

1

1

1

1

1

1

1

1

1

1

4

1

1

1

1

2

1

1

1

1

1

1

1

2

2

70-1085

70-1086

70-1087

FACTORy

70-0580

70-0581

70-0582

FACTORy

70-0579

70-1072

70-0467

70-0298

72-0066

70-0297

70-0579

70-1134

72-0066

72-0066

20-2390

78-1010

78-0072

72-0066

72-0065

FACTORy

70-0745

70-0746

30-0164

20-1520

Summary of Contents for PXV Series

Page 1: ...ooded heat exchangers to minimize fluctuations in liquid level and evaporator pressures and for liquid injection for compressor oil cooling key FEATURES PXV5 PXV15 drop in replacement valve for Sporla...

Page 2: ...und the valve bonnet and upper body while welding Socket weld fitting and valve codes require that the pipe be inserted until bottomed against the stop then backed out approximately 1 16 1 5 mm before...

Page 3: ...ON VALVE PRESSURE TRANSDUCER 10 00 2 00 POSITION PXV PXVC PT CONTROLLER INSULATION TEMPERATURE SENSOR AT 4 OR 8 O CLOCK POSITION PIPE TEMPERATURE SENSOR TO PROTECTED SUCTION DX EVAPORATOR EXPANSION VA...

Page 4: ...ler Application Figure 3 EXPANSION VALVE SURGE VESSEL PXV OR PXVW PULSE WIDTH OR TECHNI LEVEL VLT VARI LEVEL WITH MOD420 CUSTOMER SUPPLIED HANSEN FOR LIQUID LEVEL PXVC L CONTROLLER OPERATION Liquid in...

Page 5: ...VW Typical Liquid injection cooling for screw compressor application Figure 4 For systems using the PXVW valve the integral hand expansion stem capacity must be adjusted to match the capacity of the e...

Page 6: ...6 P249 OCT 2013 tYPICAL wiring diagrams DX Evaporator Control PXVC PT Using Separate Pressure Transducer and Temperature Sensor Figure 5...

Page 7: ...7 P249 OCT 2013 tYPICAL wiring diagrams DX Evaporator Control PXVC DX Using Hansen HPT 4 20 mA or Customer Supplied 4 20 mA Superheat Input Figure 6...

Page 8: ...8 P249 OCT 2013 tYPICAL wiring diagrams Temperature control Figure 7...

Page 9: ...9 P249 OCT 2013 tYPICAL wiring diagrams Liquid level control Figure 8...

Page 10: ...er Kit Above kit consists of Long life Plunger Solenoid Tube Solenoid Tube O Ring Tube Screws Coil Knob PXV Gasket Kit Above kit consists of Solenoid Tube O Ring Strainer Cap O Ring Flange Gasket Stra...

Page 11: ...Washer Packing Nut Seat O Ring PXVW Stem Kit Above kit consists of Capacity Adjustment Stem Gasket Kit Bonnet Cartridge Kit Above kit consists of Cartridge Assembly PXVW Piston Seat Kit Above kit con...

Page 12: ...ng with a drive ratchet attach the seat removal tool with the two lugs on the end 7 Remove seat by turning counterclockwise 8 Once the seat is loose withdraw the tool 9 Reverse the seat removal tool a...

Reviews: