Error Code
Test program
-
>
In test program, once short-circuit failure of thermistor is detected by controller, the E7
would occur. When E7 occurs, the drain pump will run until flowmeter keep motionless for 2
minutes . and all the other components will be stopped immediately. At
the same time, the buzzer will alarm for 30 seconds and error 7 will be shown.
E7
Short-circuit failure of thermistor
-
28 -
E8
Diverter valve fault
In the process of test program in which diverter valve should be act, if machine doesn’t
detect the feeding signal of diverter valve for 15 seconds or doesn’t detect the diverter valve
being positioned accurately in 60 seconds, the E8 would occur.
In the process of washing program in which diverter valve should be act, if machine doesn’t
detect the feeding signal of diverter valve for 15 seconds or doesn’t detect the diverter valve
being positioned accurately in 60 seconds, the diverter valve would stop and the E8 would
be set off after ending washing program.
When E8 occurs, the drain pump will run until flowmeter keep motionless for 2 minutes and
all the other components will be stopped immediately. At the same time, the buzzer will
alarm for 30 seconds and the error code will be shown.
For models equipped with diverter(alternative washing function)