Procedure
-
>
Test Program
N o.
Process
0
Intialization
1
Inlet Valve
2
Higher-speed
Washing Pump
and Heating
Element
3
Lower-speed
Washing Pump
and Dispenser
4
Regeneration
Valve
5
Drain Pump
6
finish
Procedure of Test Program
(for models controlling water filling by flowmeter)
Dis play on
t he s c reen
05
03
D escription
88
Power on, stand by
Open inlet valve and feeds with 3.6L water(45cm model feeds
with 3.0L water).
04/Temper-
ature value
Run higher-speed washing pump and 10s later run heating
element until the water temperature reaches 57℃. Then the
machine will pause.
Press Start/Pause button to jump into the next step.
F*
Buzz one sound, stop, and stand by.
2s later run lower-speed washing pump for 8s. Dispenser will act
for 45s in this step.
Open regeneration valve for 30s.
02
01
Drain for 30s.
-
25 -