To prevent the formation of a fl am-
mable gas-air mixture in the event of
a leakage in the refrigeration circuit,
the installation space must have a
minimum size of 1 m
3
per 8 g of refrig-
erant in compliance with the EN 378
standard. The amount of refrigerant
contained in your appliance can be
found on the data sheet (see ‘Techni-
cal specifi cations’ on page EN-30).
■
Refrigerant is fl ammable when spurt-
ing out and can damage the eyes. In
this case, rinse your eyes in clean wa-
ter and seek medical assistance im-
mediately.
To prevent the formation of a flammable gas-
air mixture in the event of a leakage in the
refrigeration circuit, the installation space
must have a minimum size of 1 m³ per 8 g
of refrigerant in compliance with the EN 378
standard. The amount of refrigerant con-
tained in your appliance can be found on the
data sheet at the end of this user manual.
The minimum size of the area in which your
appliance is set up is as follows: 5.25 m³.
The appliance must only be placed on a level
and firm surface. The surface must be strong
enough to support the appliance’s weight
when fully laden.
Suitable locations are dry, well-ventilated ar-
eas that are cool if possible.
Unsuitable locations are ones with direct sun-
light or which are directly next to an oven, hob
or radiator.
If underfloor heating is installed at the set-up
location, place the cooling appliance on an
insulation plate made from solid material.
Diagram: space requirement (door open)
1033mm
595mm
m
m2
80
1
m
m5
45
135°
About climate categories
• Always ensure the prescribed ambient temperature is maintained (see ‘Intended use’ on
page EN-5).
Climate category means that the appliance is intended for operation at the specified ambient
temperature.
Zone description
Code Definition
Extended temperate zone
SN
This refrigerator is designed for use at ambient temper-
atures of +10 °C to +32 °C.
Temperate zone
N
This refrigerator is designed for use at ambient temper-
atures of +16 °C to +32 °C.
Subtropical zone
ST
This refrigerator is designed for use at ambient temper-
atures of +16 °C to +38 °C.
Tropical zone
T
This refrigerator is designed for use at ambient temper-
atures of +16 °C to +43 °C.
If the room temperature drops significantly below this, the unit will not switch on as often. This
indicates that an unwelcome increase in temperature may occur.
Start-up
Page EN-24