– To prevent a flammable gas-air mixture
from forming following a leakage in the
refrigeration circuit, the installation space
must have a minimum size of 1 m
3
per 8
g of refrigerant in compliance with the EN
378 standard. The amount of refrigerant
contained in your appliance can be found
on the data sheet at the end of this user
manual.
– The appliance must only be placed on a
level and firm surface. The surface must be
strong enough to support the appliance’s
weight when fully laden.
– Suitable locations are dry, well-ventilated
areas that are cool if possible.
– Unsuitable locations are ones with direct
sunlight or which are directly next to an
oven, hob or radiator.
– The following minimum distances must be
maintained:
– to electric stoves
10 cm
– to oil and coal burning stoves
10 cm
– to other refrigeration appliances 10 cm
– to washing machines/dishwash-
ers
10 cm
– If you would like to reduce these distances,
you can fit an insulation plate between the
appliances.
– If underfloor heating is installed at the set-
up location, place the appliance on an insu-
lation plate made from solid material.
Space requirement diagram (when the door is open and when the door is closed)
Start-up