Start-up
Page GB-14
The suitable furniture
200 cm
2
200 cm
2
To achieve sufficient ventilation around the
refrigerator for safety reasons, the specifica-
tions of the necessary ventilation cross-sec-
tion must be adhered to.
Ventilation of the compressor and condenser
occurs through an opening that must be avail-
able underneath the kitchen cabinet (size of
the opening: minimum 200 cm
2
).
There must also be an opening on top of the
kitchen cabinet to make sure that air can es-
cape (size of the opening: minimum 200 cm
2
).
The installation recess must meet the follow-
ing requirements:
Height (H):
1220 to 1230 mm
Width (B):
560 mm
Depth (T):
≥ 550 mm
Distance to the wall: ≥ 38 mm
Mains cord length:
ca. 1520 mm
Ventilation chamber at the rear of the built-in
cabinet:
at least 200 cm
2
90°
The installation recess must be screwed to
the neighbouring cabinets or to the wall and
carefully aligned. The cabinet doors must be
aligned and the hinges tightened.