Summary of Contents for Evolution 25

Page 1: ......

Page 2: ...1 Introduction 2 Specifications 3 Dimension 4 Installation 5 Electrical Wiring 6 Initial Startup of the unit 7 Operation 8 Maintenance 9 Troubleshooting 10 Explode diagram INDEX POOL HEAT PUMP ...

Page 3: ...t to our customer please read this manual carefully before installing operating and troubleshooting then process accordingly This manual includes all necessary information HANSCRAFT The heat pump unit must be installed by qualified technicians from after sales center or authorized distributor Operating and maintaining according to recommended time and frequency on the manual Use only standard spar...

Page 4: ...ent A Fuse Current Advised pool volume with pool cover Advised water flux Water Pressure Drop Condenser Compressor type Water pipe in out Fan Speed Noise level 10m Noise level 1m Refrigerant Dimension Weight Net Weight Gross Weight Net Dimension Packing Dimension 6 8 10 13 1 09 1 60 2 07 6 25 6 25 6 25 4 3 6 5 8 2 1 02 1 48 1 86 4 2 4 4 4 4 4 7 7 0 9 0 10A 15A 20A 220 240V 50Hz 1PH 15 25m 25 35m 3...

Page 5: ...ation are necessary spare parts for the water system which are provided by users or installers 4 Installation 4 1 Installation illustration POOL HEAT PUMP Unit mm A B C D E F G H I Models 302 622 288 332 988 230 103 557 98 326 655 306 350 1026 340 108 620 92 EVOLUTION 60 EVOLUTION 25 EVOLUTION 40 ...

Page 6: ...eet the three factors a Good ventilation b Stable and reliable power supply c Recycled water system The difference from gas water heater it should not bring environmental pollution or have the installing problems in windy areas 4 The unit should not be installed in a limited air ventilation area or placed in a bush where it will block the air inlet These location deny the unit of a continuous sour...

Page 7: ...ers is 0 6KW per hour 2000BTU for every 5 surrounding the pipe which translates to about 3 to 5 increase in run time 2 To get the best heat exchange of heat pump unit it should be matched the normal rate of water flow recommended in specification sheet 3 It is required to increase the discharge pipe to prevent freezing in cold season to put T fitting and ball valve to facilitate changing the water...

Page 8: ... CN2 3 Remote switch Low voltage switch Remote controller High voltage switch Phase sequence protection CN3 SW1 YLW GRN YLW GRN BRN BLU YLW 1 2 V ENT G N D GND GN D G ND GND G ND KYIN FS LP HP PP 2 2 2 2 2 2 Water outlet coil temperature sensor Water inlet coil temperature sensor H coil temperature sensor eating Ambient emperature t sensor Cooling coil temperature sensor Refrigerant return tempera...

Page 9: ...witch Phase sequence protection CN3 SW1 BRN BLU YLW 12V ENT GND GND GND GND GND GND KYIN FS LP HP PP 2 2 2 2 2 2 Water outlet coil temperature sensor Water inlet coil temperature sensor H coil temperature sensor eating Ambient emperature t sensor Cooling coil temperature sensor Refrigerant return temperature sensor CN4 GND GND GND GND GND GND T6 T5 T4 T3 T2 T1 SINGLE WATER PUMP POWER 208 230V 60Hz...

Page 10: ...tart as long as HP unit is running Water Flow Switch It is equipped with a flow switch for protecting the HP unit running with adequate water flow rate It will turn on when the pool pump runs and shut it off when the pump shuts off If the pool water level higher than 1 m above or below the heat pump s automatic adjustment knob your dealer may need to adjust its initial startup Time Delay HP unit s...

Page 11: ...et operation parameter LED display wil show real time if HP unit is switched off 1 Press and hold in for 5 seconds to enter operating parameter setting interface 2 Under parameter setting press and to choose parameter below from 0 to A press again then press or to start setting parameters see operation parameter table and press to confirm Leave it 8 seconds LED will display water in temperature un...

Page 12: ...10 POOL HEAT PUMP 1 0 HEAT 1 0 HEAT Gas return temp Ambient temp 7 Parameter L Mode inlet water temperature correction Default setting 00 ...

Page 13: ...ng water temperature B Under standby status 1 Press and hold in for 5 seconds until parameters flash to enter operating setting 2 Press or to reach Parameter 1 3 Press again 4 Press or to set temperature 5 Press to confirm and wait for 8 seconds Machine will reset new temperature 7 4 Water temperature setting 1 0 1 0 MODE HEAT Parameter 1 To set the entering water temp under heating mode 15 35 def...

Page 14: ...o adjust then press again to store the new data 7 7 Time setting Press to set the time and press and to adjust the time Timer on setting the time Press the 7 8 Timer off setting the off time 1 0 1 0 12 7 10 System reset function Press and at the same time for 10s parameter from 0 to L to be reset to default 7 9 Cancel Timer Function Press or first then press to cancel timer on or timer off setting...

Page 15: ...essary to put an extra 3 phase transfer device for 3 phase water pump ATTENTION HP running parameters must be checked after installation and before first used When the LED on it will displays water inlet temperature When the LED off it will displays OFF When the LED on the water temp could be changed 0 Heat 15 35 15 40 POOL HEAT PUMP Mode 0 heat 1 heat and cool L Inlet water temperature correction...

Page 16: ... if heat pump starts to operate abnormally you should turn it off and contact with qualified technicians 6 You should the water from water pump and other water system to prevent from the freezing damage in winter seasons 7 8 drain The heat pump and all associated pipe work must be drained down during winter or freezing conditions Always flush with clean water and check thoroughly before recommissi...

Page 17: ...nd low pressure protection three time in half an hour 2 If the LED display the EE4 Above those matter you can cut off the power and restart the unit again or take it to maintain 9 1 Error code display on LED wire controller POOL HEAT PUMP ON ...

Page 18: ...de verifying the water inlet and outlet temperature 3 replace defect main controller Short running LED displays actual water temperature no Error code displays 1 fan NO running 2 air ventilation is not enough 3 refrigerant is not enough 1 Check the cable connections between the motor and fan if necessary it should be replaced 2 Check the location of heat pump unit and eliminate all obstacles to ma...

Page 19: ...10 Exploded Diagram POOL HEAT PUMP 17 ...

Page 20: ...ring clip Water inlet cover Retainer ring blue Water outlet cover Retainer ring red Wiring cover Right panel plastic Pillar 5 Back panel plastic Ambient temp sensor Ambient temp sensor clip Low pressure switch Gas return pipe Pipe heat exchanger to 4 way valve Separator moudle Cannula clip of evaporator temp sensor Evaporator temp sensor Gas collecting pipe Filter moudle Base tray Isolation panel ...

Page 21: ...POOL HEAT PUMP NOTE ...

Page 22: ......