Warnings / Alerts (continued)
Warning / Alert
Alert Message
Description / Solution
Motor over-temp shutdown
Pump motor is over temp. In
shutdown.
The pump motor has over-heated, check to make sure the motor fans are
plugged in and operating properly. Ensure that nothing is blocking the vents in
the side panels.
Outlet pressure sensor fault
Outlet pressure sensor fault.
Check sensor.
The outlet pressure sensor is not providing a reading. Check the wire harness
connection to the sensor. Replace the sensor, if necessary.
Pump motor controller
shutdown
Pump motor controller fault. In
shutdown.
The pump motor controller is not responding. Perform a power cycle by
unplugging the unit from the wall, wait 60 seconds, then plug the unit back in. If
this does not resolve the issue, replace the e-box.
Pump speed fault shutdown Pump speed fault. In shutdown.
The pump speed is not as expected. Perform a power cycle by unplugging the
unit from the power source, wait 60 seconds, then reconnect the system to
power. If this does not resolve the issue, replace the pump.
Solenoid driver fault
Solenoid driver fault.
There is an issue with the internal solenoid driver. . Perform a power cycle by
unplugging the unit from the power source, wait 60 seconds, then reconnect the
system to power. If this does not resolve the issue, replace the e-box.
Solenoid fault
Check drain solenoid #1-4.
The system has detected a fault in one of the drain solenoids. Check the drain
solenoid indicated to ensure it is functioning properly.
Zero rejection mitigation
Zero rejection mitigation
–
check drain manifold.
The system has detected zero rejection at the previous TDS setting and
automatically increased the TDS range to prevent membrane fouling. Check
the drain manifold to ensure it is functioning properly, then adjust the TDS
range back to the original setting to clear the alert.