2 (20)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The product is not designed to be used with steam
baths!
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• The installation dimensions stated in these installation
instructions are ideal for people of approximately
1800 mm in body height. The dimensions can be al-
tered if required. In this case, pay attention to the fact
that a change of installation height will also change
the minimum height, and that the altered mounting
dimensions must be taken into consideration.
• Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
English
only suitable for concrete. For another wall construc-
tions the manufacturer's indications of the dowel
manufacturer have to be taken into account.
• The filter insert must be use to protect the shower
against incoming dirt by pipework. Incoming dirt leads
to defects or/and can damage parts of the shower;
such caused faults voids all liability and guarantee
claims.
• If required, the bottom part of the pipe between the
fixture and the shower head can be shortened with a
fine-toothed saw.
• The shower arm of the head shower can only be
adjusted to the desired angle once during installa-
tion. Subsequent adjustment during showering is not
possible.
Assembly
(see page 6)
Pressure and permeability test
The connections of the thermostatic mixer should be
tested regular after installation.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,15 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Centre distance:
160 mm
Connections M 26x1,5:
cold right - hot left
Thermal disinfection:
max. 70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking water!
Summary of Contents for Verso 220 Showerpipe 27290000
Page 7: ...7 20 Montage 6 675 875 mm ...
Page 10: ...10 20 Justierung 1 2 3 4 ...
Page 12: ...12 20 Bedienung öffnen öppna schließen stänga 2 1 öffnen öppna 1 2 kalt kallt warm varmt ...
Page 13: ...13 20 Bedienung 1 2a 2b 2 1 Verso Vario 28779000 ...
Page 14: ...14 20 SW 6 mm 2 3 4 1 Wartung 1 2 1 2 3 SW 2 5 mm SW 6 mm 1 2 3 4 5 ...
Page 15: ...15 20 4 3 5 SW 6 mm 1 23 mm 6 7 8 9 2 3 2 1 2 5 mm 6 mm ...
Page 16: ...16 20 Reinigung SW 2 mm SW 17 mm 1 2 SW 5 mm 1 1 2 2 2 3 4 20 mm 5 6 ...
Page 17: ...17 20 Reinigung SW 2 mm SW 17 mm SW 5 mm 1 2 1 2 1 min 9 10 11 7 8 ...