background image

2 (20)

 

Safety Notes

 

Gloves should be worn during installation to prevent 
crushing and cutting injuries.

 

The arm of the shower head is intended only to hold 
the shower head. Do not load it down with other 
objects!

 

Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower 
system without proper supervision. Persons under 
the influence of alcohol or drugs are prohibited from 
using this shower system.

 

Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate 
distance must be kept between the shower and you.

 

The product may not be used as a holding handle. A 
separate handle must be installed.

 

The shower system may only be used for bathing, 
hygienic and body cleaning purposes.

 

The hot and cold supplies must be of equal pres-
sures. 

Installation Instructions

• Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 
surface damage will be honoured.

• The product is not designed to be used with steam 

baths!

• The pipes and the fixture must be installed, flushed 

and tested as per the applicable standards.

• The plumbing codes applicable in the respective 

countries must be oberserved.

• The installation dimensions stated in these installation 

instructions are ideal for people of approximately 
1800 mm in body height. The dimensions can be al-
tered if required. In this case, pay attention to the fact 
that a change of installation height will also change 
the minimum height, and that the altered mounting 
dimensions must be taken into consideration.

• Where the contractor mounts the product, he should 

ensure that the entire area of the wall to which the 
mounting plate is to be fitted, is flat (no projecting 
joints or tiles sticking out), that the structure of the wall 
is suitable for the installation of the product and has 
no weak points. The enclosed screws and dowels are 

English

only suitable for concrete. For another wall construc-
tions the manufacturer's indications of the dowel 
manufacturer have to be taken into account.

• The filter insert must be use to protect the shower 

against incoming dirt by pipework. Incoming dirt leads 
to defects or/and can damage parts of the shower; 
such caused faults voids all liability and guarantee 
claims.

• If required, the bottom part of the pipe between the 

fixture and the shower head can be shortened with a 
fine-toothed saw.

• The shower arm of the head shower can only  be 

adjusted to the desired angle once during installa-
tion. Subsequent adjustment during showering is not 
possible. 

Assembly 

(see page 6)

 

Pressure and permeability test

The connections of the thermostatic mixer should be 
tested regular after installation. 

Technical Data

Operating pressure:  

max. 1 MPa

Recommended operating pressure:  

0,15 - 0,5 MPa

Test pressure:  

1,6 MPa

(1 MPa = 10 bar = 147 PSI)
Hot water temperature:  

max. 80°C

Recommended hot water temp.: 

65°C

Centre distance:  

160 mm

Connections M 26x1,5:  

cold right - hot left

Thermal disinfection:  

max. 70°C / 4 min 

• Safety against backflow
• The product is exclusively designed for drinking water!

Summary of Contents for Verso 220 Showerpipe 27290000

Page 1: ...on 11 Operation 12 13 Maintenance 14 15 Cleaning 16 18 Dimensions 19 Flow diagram 19 Spare parts 20 Contact information 20 SV Innehållsförtäckning 1 Bruksanvisning Monteringsanvisning 4 Felsökning 5 Montering 6 9 Inställning av maxtemperatur 10 Safety Function 11 Hantering 12 13 Skötsel 14 15 Rengöring 16 18 Måttskiss 19 Flödesschema 19 Reservdelar 20 Kontaktinformation 20 ...

Page 2: ...change of installation height will also change the minimum height and that the altered mounting dimensions must be taken into consideration Where the contractor mounts the product he should ensure that the entire area of the wall to which the mounting plate is to be fitted is flat no projecting joints or tiles sticking out that the structure of the wall is suitable for the installation of the prod...

Page 3: ...sary if the temperature measured at the take off point differs from the temperature set on the scale Symbol description Special accessories order as an extra 95163000 tile matching disk chrome plated Fault Cause Remedy Insufficient water Supply pressure inadequate Check water pressure If a pump has been installed check to see if the pump is working Filters are dirty 97367000 Cleaning the filter in...

Page 4: ...en ändras när monteringshöjden blir en annan och att hänsyn måste tas till de ändrade anslutnings måtten När kvalificerad fackpersonal monterar produkten är det viktigt att tänka på att monteringsytan är plan i alla delar av arbetsytan inga fogar som sticker ut eller klinkerförskjutningar att väggkonstruktionen passar till montering av produkten samt att den inte har svaga punkter Medföljande skru...

Page 5: ...trolleras och ställas in på den temperatur som kunden vill ha En korrige ring krävs när den uppmätta temperaturen vid tappstället avviker från den temperatur som är inställd på termostaten Symbolförklaring Specialtillbehör medföljer ej leveransen 95163000 Kakelutjämningsbricka krom Störning Orsak Åtgärd För lite vatten Vattentrycket är för lågt Kontrollera ledningstryck Smutsfiltren är igensmutsad...

Page 6: ...Montage 1 2 3 4 5 2 5 mm 23 mm 2 5 mm The nuts of the installation plate must be tightened to the manufacturer s instructions Muttrarna dras åt enligt monteringsanvisningen från leverantören av blandarfäste ...

Page 7: ...7 20 Montage 6 675 875 mm ...

Page 8: ... be waterproof mould resistant and age resistant Vid montering på regelvägg måste väggen alltid förstär kas Alla skruvinfästningar skall ske i massiv konstruktion t ex betong i reglar eller särskild konstruktionsdetalj Skru vinfästning får inte göras enbart i golv eller väggskiva Krav på tätning gäller både i våtzon 1 och 2 Material för tätning ska fästa mot underlaget och vara vattenbestän digt m...

Page 9: ...9 20 Montage SW 6 mm 1 2 1 2 N r 1 0 4 7 6 2 2 0 A r m a t u r e n f e t t G r e a s e 9 10 2 1 11 12 13 94246000 94246000 SW 17 mm SW 2 mm ...

Page 10: ...10 20 Justierung 1 2 3 4 ...

Page 11: ...11 20 3mm 2 Nm Safety Function for example 42 C till exempel 42 C 3 2 5 6 4 3mm 1 2 1 1 2 2 1 2 2 1 3 3 ...

Page 12: ...12 20 Bedienung öffnen öppna schließen stänga 2 1 öffnen öppna 1 2 kalt kallt warm varmt ...

Page 13: ...13 20 Bedienung 1 2a 2b 2 1 Verso Vario 28779000 ...

Page 14: ...14 20 SW 6 mm 2 3 4 1 Wartung 1 2 1 2 3 SW 2 5 mm SW 6 mm 1 2 3 4 5 ...

Page 15: ...15 20 4 3 5 SW 6 mm 1 23 mm 6 7 8 9 2 3 2 1 2 5 mm 6 mm ...

Page 16: ...16 20 Reinigung SW 2 mm SW 17 mm 1 2 SW 5 mm 1 1 2 2 2 3 4 20 mm 5 6 ...

Page 17: ...17 20 Reinigung SW 2 mm SW 17 mm SW 5 mm 1 2 1 2 1 min 9 10 11 7 8 ...

Page 18: ...18 20 Reinigung 2 1 1 min 1 2 3 ...

Page 19: ...115 10 0 0 10 0 0 m i n 2 5 m i n 2 5 305 3 8 Ø 160 Ø 41 22 Ø 353 460 7 75 0 8 5 0 293 10 91 10 0 0 26 26 M 2 6 x 1 5 57 41 84 Ø220 Verso 220 Showerpipe 27290000 Verso 220 Showerpipe 27290000 2 1 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 bar 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec 80 80 ...

Page 20: ...46000 98913000 95927000 98390000 26x1 5 98390000 26x1 5 98283000 98282000 98129000 14x2 98058000 28276000 97367000 98213000 9x1 98137000 17x1 5 95835000 96737000 Hansgrohe AB Svangatn 2B 416 68 Göteborg Tele 46 0 31 216600 Fax 46 0 31 190103 E post info hansgrohe se Internet www hansgrohe se 1 2016 9 01229 01 28779000 94246000 98942000 95794000 98419000 7x2 97536000 97606000 98941000 26464000 ...

Reviews: