4
Assembly see page 32
Cleaning
(see page 36)
Maintenance
(see page 37)
The check valves must be checked regularly according to DIN EN
1717 in accordance with national or regional regulations (at least once
a year).
Operation
(see page 35)
• Hansgrohe recommends not to use as drinking water the first half
liter of water drawn in the morning or after a prolonged period of
non-use.
• Minor leaking may occur briefly at the spout when opening the
fitting via the lever.
• Use the lever to open the tap and set the desired temperature. The
water flow can be paused by pressing the Select button on the face
side of the spout. When the tap is not used for a longer period of
time, f.e. when retiring at night or leaving the house, it must be closed
completely by means of the lever.
Flow diagram
(see page 31)
Dimensions
(see page 31)
Adjustment
(see page 34)
To adjust the hot water limiter. Using a hot water limiter in combination
with a continuous flow water heater is not recommended.
Symbol description
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be observed.
• During initial start-up and after servicing, air in the fittings can cause noise. After
switching the jet on and off about 15 times, the noise will stop.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
English
Do not use silicone containing acetic acid!
Spare parts
(see page 38)
XXX = Colors
000 = chrome plated
800 = stainless steel optic
Fault
Cause
Remedy
No water
-
No plunger (A) for the backflow preventer was in-
stalled
-
Install plunger (A) (see page 38)
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping
-
Cartridge defective
-
Exchange cartridge
Low flow with Select valve after valve replacement
-
Improper Select valve installed
-
Replace Select valve #98462000 (see page 38)
Water escaping in area of swivel spout
-
O-ring defective
-
Exchange O-ring
Water escaping at the threaded base
-
connection hoses not completely screwed into basic
body
-
Tighten connection hoses by hand
-
O-ring at the connection hose defective.
-
Exchange O-ring
Hot water temperature too low
-
Hot water limiter incorrectly set
-
Set hot water limiter
Select button stiff
-
Select button soiled
-
Clean Select button and grease 19x1,5 O-ring (see
page 38)
Test certificate
(see page 40)