Fault

Cause

Remedy

Insufficient water

- Supply pressure inadequate

- Check water pressure (If a pump has been installed 

check to see if the pump is working).

- Regulator filter dirty

- Clean filter in front of the mixer and on the MTC-ther-

mo cartridge

- Shower filter seal dirty

- Clean filter seal between shower and hose

Crossflow, hot water being forced into cold water pipe, 

or vice versa, when mixer is closed

- Backflow preventers dirty or leaking

- Clean backflow preventers, exchange if necessary

Spout temperature does not correspond with tempera-

ture set

- Thermostat has not been adjusted

- Adjust thermostat

- Hot water temperature too low

- Increase hot water temperature to 42 °C to 60 °C

Temperature regulation not possible

- thermo cartridge calcified

- Exchange thermo cartridge

Instantaneous heater didn't work with thermostat

- Filters are dirty

- Clean the filter / exchange filter

- check valve hasn't moved back

- Exchange check valves

4

English

Assembly 

(see page 33)

Safety Notes

 

Gloves should be worn during installation to prevent crushing and cutting 

injuries.

 

The product may only be used for bathing, hygienic and body cleaning 

purposes.

 

The arm of the shower head is intended only to hold the shower head. Do not 

load it down with other objects!

 

Children as well as adults with physical, mental and/or sensoric impairments 

must not use this product without proper supervision. Persons under the influence 

of alcohol or drugs are prohibited from using this product.

 

Do not allow the streams of the shower touch sensitive body parts (such as your 

eyes). An adequate distance must be kept between the shower and you.

 

The product may not be used as a holding handle. A separate handle must be 

installed.

 

The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport damages. After it has been 

installed, no transport or surface damage will be honoured.

• The pipes and the fixture must be installed, flushed and tested as per the 

applicable standards.

• The plumbing codes applicable in the respective countries must be observed.

• The installation dimensions stated in these installation instructions are ideal for 

people of approximately 1800 mm in body height. The dimensions can be 

altered if required. In this case, pay attention to the fact that a change of 

installation height will also change the minimum height, and that the altered 

mounting dimensions must be taken into consideration.

• During installation of the product by qualified trained personnel, make sure that 

the entire fastening surface is even and smooth (no protruding seams or tile 

offset), that the finish of the wall is suitable to apply the product and has no weak 

points.

• The mesh washer must be insert to protect the shower against incoming dirt by 

pipework. Incoming dirt leads to defects or/and can damage parts of the 

shower; such caused faults voids all liability and guarantee claims.

• The product is not designed to be used with steam baths!

• If required, the bottom part of the pipe between the fixture and the shower head 

can be shortened with a fine-toothed saw.

• If the continuous water heater causes any problems, or you have different water 

pressures you must install a water limiter to the cold supply, (ordered separate-

ly,article number 97510000).

• The shower arm of the head shower can only be adjusted to the desired angle 

once during installation. Subsequent adjustment during showering is not possible.

Technical Data

Operating pressure: 

max. 1 MPa

Recommended operating pressure: 

0,1 - 0,5 MPa

Test pressure: 

1,6 MPa

 

(1 MPa = 10 bar = 147 PSI)

Hot water temperature: 

max. 60°C

Centre distance: 

150±12 mm

Connections G 1/2: 

cold right - hot left

Thermal disinfection: 

70°C / 4 min

• Safety against backflow

• The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!

Safety Function 

(see page 36)

The desired maximum temperature for example max. 42°C can be pre-set thanks to 

the safety function.

Adjustment 

(see page 36)

After the installation, the output temperature of the thermostat must be checked. A 

correction is necessary if the temperature measured at the output differs from the 

temperature set on the thermostat.

Maintenance 

(see page 38)

• The check valves must be checked regularly according to EN 806-5 in accord-

ance with national or regional regulations (at least once a year).

Dimensions 

(see page 39)

Flow diagram 

(see page 39)

  Hand shower

  Overhead shower

Spare parts 

(see page 40)

Cleaning 

(see page 35)

Operation 

(see page 37)

To empty the overhead shower after use, hold it in a slightly inclined position.

Summary of Contents for Stamis S 240 Showerpipe 26809000

Page 1: ...SK N vod na pou itie Mont ny n vod 12 ZH 13 RU 14 FI K ytt ohje Asennusohje 15 SV Bruksanvisning Monteringsanvisning 16 LT Vartotojo instrukcija Montavimo instrukcijos 17 HR Upute za uporabu Uputstva...

Page 2: ...mm K rpergr e und m ssen gegebenenfalls angepasst werden Hierbei ist darauf zu achten dass sich bei ge nderter Montageh he die Mindesth he ndert und die nderung der Anschlussma e ber cksichtigt werden...

Page 3: ...u fait qu un changement de hauteur modifie la hauteur minimum et que la modification des cotes de raccord doit entrer en ligne de compte Lors du montage de ce produit par du personnel qualifi veiller...

Page 4: ...1800 mm in body height The dimensions can be altered if required In this case pay attention to the fact that a change of installation height will also change the minimum height and that the altered m...

Page 5: ...te vanno adattate A ci bisogna fare attenzione che ad altezza di montaggio cambiata l altezza minima necessaria indicata cambia e che bisogna considerare la modifica delle quote di collegamento Per il...

Page 6: ...r en cuenta que en caso de modificaci n de la altura de montaje cambia la altura m nima y habr que adaptar las medidas de conexi n Durante el montaje del producto mediante personal especializado se de...

Page 7: ...orden dat bij een gewijzigde montagehoogte ook de minimum hoogte verandert en dat de aansluitmaten overeenkomstig moeten worden aangepast Bij de montage van het product door gekwalificeerd vakpersonee...

Page 8: ...ivet fald tilpasses Herved skal der tages hensyn til at den mindste h jde i tilf lde af en ndret monteringsh jde ndres og at der skal tages hensyn til de ndrede tilslutningsm l Ved montering af produk...

Page 9: ...nstru es de montagem s o ideais para pessoas com uma altura aprox 1800 mm e t m que ser eventualmente adaptadas Neste contexto deve ter se em aten o que altera es na altura de montagem obrigam a alter...

Page 10: ...b o wzro cie si gaj cym ok 1800 mm i w razie konieczno ci nale y je dostosowa Nale y przy tym zwr ci uwag na fakt i przy zmienionej wysoko ci monta u zmienia si minimalna wysoko a tak e ulegaj zmiani...

Page 11: ...1800 mm a v p pad pot eby je nutn je p izp sobit P i tom je zapot eb db t nato e se p i zm n n v ce mont e zm n po adovan minim ln v ka a e je t eba br t ohled na p ipojovac rozm ry P i mont i produk...

Page 12: ...vy pribli ne 1800 mm a v pr pade potreby je nutn ich prisp sobi Pritom je nutn si uvedomi e pri zmenenej v ke mont e sa men minim lna v ka a a je nutn dba na rozmery rozmiestnenia pr pojok Pri mont i...

Page 13: ...42 C 60 C 13 33 1800 mm 97510000 1 MPa 0 1 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 60 C 150 12 mm G 1 2 70 C 4 36 42 C 36 38 EN 806 5 39 39 40 35 37...

Page 14: ...42 60 14 33 1800 Hansgrohe 97510000 1 0 1 0 5 1 6 1 10 bar 147 PSI 60 C 150 12 G 1 2 70 C 4 Safety Function 36 Safety Function 42 C 36 38 EN 806 5 39 39 40 35 37...

Page 15: ...t n 180 cm n pituiselle henkil lle ja niit on tarvittaessa muutettava T ss on otettava huomioon ett asennuskor keuden muuttuessa muuttuu my s v himm iskorkeus ja muutos on otettava huomioon liit nt je...

Page 16: ...ktigt att t nka p att den minsta h jden ndras n r monteringsh jden blir en annan och att h nsyn m ste tas till de ndrade anslutningsm tten N r kvalificerad fackpersonal monterar produkten r det viktig...

Page 17: ...ealiai tinka 1800 mm gio mon ms Galima keisti auk t bet tuomet kei iasi minimalus rekomenduojamas patalpos auk tis ir turi b ti atsi velgta vandens jungties matmen pasikeitim Atlikdami montavimo darbu...

Page 18: ...lne su za osobe visine oko 1800 mm te se prema potrebi moraju prilagoditi konkretnoj visini korisnika Pritom valja uzeti u obzir da se u slu aju promjene monta ne visine mijenja i minimalna visina kao...

Page 19: ...sunt ideale pentru persoane cu o n l ime de cca 1800 mm i trebuie modificate dac este cazul Aici trebuie s ine i cont de modificarea n l imii de montare deoarece n acest caz se va modifica i n l imea...

Page 20: ...42 C 60 C 20 33 1800 mm Hansgrohe 97510000 1 MPa 0 1 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 60 C 150 12 mm G 1 2 70 C 4 min Safety Function 36 Safety Function 42 C 36 38 EN 806 5 39 39 40 35 37...

Page 21: ...odilu za monta o navedene mere so idealne za osebe visoke pribl 1800 mm in jih je treba po potrebi prilagoditi Pri tem morate paziti na to da se pri spremenjeni monta ni vi ini spremeni tudi minimalna...

Page 22: ...aldusm dud on ideaalsed u 1800 mm pikkustele inimestele ning vajadusel tuleb neid kohandada Seejuures tuleb silmas pidada et muutunud paigaldusk rguse korral muutub ka minimaalne k rgus ning tuleb arv...

Page 23: ...zm ri ir ide li piem roti person m kuru augums ir apm 1800 mm Nepiecie am bas gad jum ie izm ri ir j piel go eit ir j em v r ka mainoties mont as augstumam main s ar minim lais augstums un j em v r ar...

Page 24: ...dealne su za osobe visine oko 1800 mm tako da se po potrebi moraju prilagoditi konkretnoj visini korisnika Pri tome treba uzeti u obzir da se prilikom promene monta ne visine menja i minimalna visina...

Page 25: ...m n dvendig Her skal man passe p at ved endrede monteringsm lene blir minsteh yden endret og det m tas hensyn til de endrede tilkoblingsm lene Under monteringen av produktet gjort av kvalifisert fagpe...

Page 26: ...42 C 60 C 26 33 1800 Hansgrohe 97510000 1 0 1 0 5 1 6 1 10 bar 147 PSI 60 C 150 12 G 1 2 70 C 4 Safety Function 36 Safety Function 42 C 36 38 EN 806 5 39 39 40 35 37...

Page 27: ...1 42 C 60 C 27 33 0 1 MPa 1800 mm 97510000 1 MPa 0 1 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 60 C 150 12 mm G 1 2 70 C 4 Safety Function 36 Safety Function 42 C 36 38 EN 806 5 1 39 39 40 35 37...

Page 28: ...MTC thermo 42 C 60 C 28 33 1800 97510000 1 0 1 0 5 1 6 1 10 147 PSI 60 C 150 12 G 1 2 70 C 4 Safety Function 36 42 C 36 38 EN 806 5 39 39 40 35 37...

Page 29: ...60 42 29 33 1800 97510000 1 0 5 0 1 1 6 PSI 147 10 1 C 60 12 150 G 1 2 4 70 C 36 42 36 38 EN 806 5 39 39 40 35 37...

Page 30: ...lmemektedir Borular n ve armat r n montaj y kanmas ve kontrol ge erli normlara g re yap lmal d r lkelerde ge erli kurulum y netmeliklerine riayet edilmelidir Montaj k lavuzunda belirtilen montaj l ler...

Page 31: ...k a zuhany funkci it Az ezekb l ad d k rok rt a Hansgrohe nem felel A term ket nem g zf rd vel egy ttes haszn latra tervezt k Sz ks g eset n a cs vet a csap s a zuhanyfej k z tt az als r szen egy fino...

Page 32: ...MTC thermo 60 42 32 33 1 80 97510000 MPa 1 MPa 0 5 0 1 MPa 1 6 MPa 10 bar 147 PSI 1 60 C 150 12 G 1 2 70 C 4 36 42 36 38 EN 806 5 39 39 40 35 37...

Page 33: ...33 X 36 mm X 36 X 1 1 2 2 1 2 3a 3b 4 5 6 36 mm max 39 mm max 5 mm 7 8 750 850 9 1 2 6 mm 10 60 mm 11 SW 24 mm SW 30 mm 17 Nm Silicone A r m a t u r e n f e t t G r e a s e 2 1 12 13...

Page 34: ...34 2 1 15 16 17 14 CLICK SW 17 mm 10 Nm...

Page 35: ...spray nozzles to remove lime scale IT Facile da pulire Il calcare viene eliminato semplicemente dagli ugelli elastici in silicone ES F cil aseo La cal se puede retirar sencillamente frotando con los...

Page 36: ...36 max 10 min 20 mm 1 min 94246000 4 Nm max 10 min 20 mm 1 5 3 2 4 1 4 6 5 1 2 1 3 4 2 5 6 SW 3 mm SW 3 mm SW 3 mm 2 Nm z B 42 C for example 42 C 2 3 1 2 SW 3 mm 2 Nm...

Page 37: ...37 1 2 3 2 1 1 2 1 MonoRain PowderRain IntenseRain 1 2 40 C 2...

Page 38: ...e t t G r e a s e 1 2 3 4 5 SW 30 mm SW 30 mm 17 Nm 1 SW 10 mm 1 2 3 6 7 8 9 10 4 5 SW 10 mm 20 Nm Rot Rouge Red Rosso Rojo Rood R d Vermelho Czerwony erven Punainen R d Raudona Crvena Ro u K Rde a Pu...

Page 39: ...104 63 353 15 15 750 850 470 1000 209 22 85 42 150 12 240 296 1093 bar 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12...

Page 40: ...sgrohe com 12 2023 9 01506 01 94246000 26723000 92975000 92366000 92444000 28276000 98058000 94282000 95041000 96509000 92836000 92836000 95392000 98129000 14x2 94285000 98137000 17x1 5 96737000 96922...

Reviews: