![Hans Grohe ShowerTablet 350 13102 Series Instructions For Use/Assembly Instructions Download Page 4](http://html.mh-extra.com/html/hans-grohe/showertablet-350-13102-series/showertablet-350-13102-series_instructions-for-use-assembly-instructions_2102749004.webp)
Assembly
(see page 31)
Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Regulator filter dirty
- Clean filter in front of the mixer and on the MTC-
thermo cartridge
- Shower filter seal dirty
- Clean filter seal between shower and hose
Crossflow, hot water being forced into cold water pipe,
or vice versa, when mixer is closed
- Backflow preventers dirty or leaking
- Clean backflow preventers, exchange if necessary
Spout temperature does not correspond with tempera-
ture set
- Thermostat has not been adjusted
- Adjust thermostat
- Hot water temperature too low
- Increase hot water temperature to 42 ºC to 65 ºC
Temperature regulation not possible
- thermo cartridge calcified
- Exchange thermo cartridge
- Hot and cold supplies are reversed
- change connections
Instantaneous heater didn't work with thermostat
- Filters are dirty
- Clean the filter / exchange filter
- check valve hasn't moved back
- Exchange check valves
- Flow limiter in handshower isn’t removed
- Remove flow limiter
Shower or spout dripping
- Dirt or sedimentation on valve seat, shut-off unit dam-
aged
- Exchange shut-off unit
Cleaning
(see page 39)
Flow diagram
(see page 34)
Shower outlet
Tub outlet
Dimensions
(see page 34)
Operation
(see page 36)
Maintenance
(see page 38)
• To guarantee the smooth running of the thermostat, it is necessary
from time to time to turn the thermostat from total hot to total cold.
• The mixer is equipped with check valves. The check valves must be
checked regularly according to DIN EN 1717 in accordance with
national or regional regulations (at least once a year).
Adjustment
(see page 32)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Safety Function
(see page 33)
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
Do not use silicone containing acetic acid!
Symbol description
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The shower system may only be used for bathing, hygienic and body cleaning
purposes.
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be oberserved.
• During installation of the product by qualified trained personnel, make sure that
the entire fastening surface is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the product and has no weak
points.
• The product is not designed to be used with steam baths!
Thermostatic mixer in conjunction with combination boilers
• If fitting a hand shower remove the water limiter from the shower.
Special information for UK
If installing this product with a pump, please be aware that it has to have negative
head switching. This product will not function with a positive head pump.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Centre distance:
150±12 mm
Connections R 1/2
cold right - hot left
Thermal disinfection:
max. 70°C / 4 min
Safety against backflow
The product is exclusively designed for drinking water!
English
Spare parts
(see page 35)
4