Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking
water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 36)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Dimensions
(see page 37)
Flow diagram
(see page 37)
free flow
Spare parts
(see page 38)
XXX = Colors
000 = Chrome Plated
670 = Matt Black
Special accessories
(order as an extra)
extension #32498000 (see page 38)
Cleaning
(see page 39)
Operation
(see page 40)
Test certificate
(see page 40)
Assembly
(see page 35)
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Diverter not operating
- Residue
- Clean converter / grease O-rings
- Water pressure to low
- Increase water pressure
- Diverter defective
- Exchange diverter
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
- Hot water limiter incorrectly set
- Set hot water limiter
- Crossflow
- Exchange cartridge
www.divapor.com