4
English
Assembly
(see page 40)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower may only be used for bathing, hygiene
and body cleaning purposes.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The product is not designed to be used with steam
baths!
Technical Data
Operating pressure:
max. 0,6 MPa
Recommended operating pressure:
0,15 - 0,4 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Dimensions
(see page 38)
Installation example
(see page 32)
Flow diagram
(see page 32)
Spare parts
(see page 48)
Cleaning
(see page 43)
i
Fault
Cause
Remedy
Head shower extremely leaky
- Head shower soiled / scaled
- Clean / descale head shower
(see page 43)