4
English
Assembly
(see page 34)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!
The product may only be used for bathing, hygienic
and body cleaning purposes.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• During installation of the product by qualified trained
personnel, make sure that the entire fastening surface
is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply
the product and has no weak points.
• The mesh washers must be installed to protect
against incoming dirt by pipework. Incoming dirt can
impair the function and/or lead to damages on
functional parts of the fixture; Hansgrohe will not be
held liable for resulting damages.
• The product is not designed to be used with steam
baths!
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure (26230XXX)
0,2
- 0,4 MPa
Recommended operating pressure (26226XXX)
0,14
- 0,4 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
• The product is exclusively designed for drinking
water!
• This mixer cannot be used in conjunction with
hydraulically, electronically or thermally controlled
instantaneous heaters.
Symbol description
Do not use silicone containing acetic acid!
Dimensions
(see page 39)
Flow diagram
(see page 40)
Operation
(see page 36)
Installation example
(see page 32)
The wall must be reinforced in this area.
Center shower tub
Warm water
Cold water
Spare parts
(see page 47)
XXX = Colors
000 = Chrome Plated
700 = Matt White
Cleaning
(see page 42)
Test certificate
(see page 48)
i
X
Fault
Cause
Remedy
Head shower extremely leaky
- Head shower soiled / scaled
- Clean / descale head shower
Summary of Contents for Rainfinity 250 1jet 26226 Series
Page 33: ...33 i DN 15 1 2 DN 20 3 4 26243XXX 26864XXX 1531118X 15381XXX ...
Page 34: ...34 2 2 2 3 1 1 3 4 2 2 1 1 5 6 1 2 60 Ø 6 mm 1 R 1 2 SW 10 mm SW 10 mm SW 10 mm 13 mm 28 mm ...
Page 35: ...35 7 9 1 3 2 4 1 8 70 mm 60 mm 1 2 10 click 3 11 1 2 2 ...
Page 38: ...38 5 1 2 1 2 4 click 3 ...
Page 39: ...39 2050 500 870 0 3MPa Rainfinity 250 1jet 26226XXX Rainfinity 360 1jet 26230XXX ...
Page 44: ...44 4 2 3 0 1 1 2 2 A1 A3 A2 A4 1 2 A5 click 3 A6 1 2 ...
Page 45: ...45 1 1 2 2 B1 B2 B4 B5 B3 1 3 2 1 min A7 ...
Page 46: ...46 B8 1 2 3 B7 70 mm 60 mm B11 1 min 1 2 B9 click 3 B10 1 2 B6 ...