Assembly see page 31
Fault
Cause
Remedy
Insufficient water
-
Supply pressure inadequate
-
Check water pressure (If a pump has been installed
check to see if the pump is working).
-
Filters are dirty (96922000)
-
Clean filter in front of the mixer and on the MTC-
thermo cartridge (96922000)
-
filter insert shower dirty
-
Shower filter seal dirty
-
Clean filter insert between shower and hose
-
Clean filter seal between shower and hose
Crossflow, hot water being forced into cold water pipe,
or vice versa, when mixer is closed
-
Backflow preventers dirty or leaking
-
Clean backflow preventers, exchange if necessary
Spout temperature does not correspond with tempera-
ture set
-
Thermostat has not been adjusted
-
Adjust thermostat
-
Hot water temperature too low
-
Increase hot water temperature to 42 ºC to 65 ºC
Temperature regulation not possible
-
thermo cartridge calcified
-
Exchange thermo cartridge
Instantaneous heater didn't work with thermostat
-
Filters are dirty
-
Clean the filter / exchange filter
-
check valve hasn't moved back
-
Exchange check valves
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
Children as well as adults with physical, mental and/or sensoric impairments
must not use this shower system without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this shower system.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The shower system may only be used for bathing, hygienic and body cleaning
purposes.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be oberserved.
• The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be
altered if required. In this case, pay attention to the fact that a change of instal-
lation height will also change the minimum height, and that the altered mounting
dimensions must be taken into consideration.
• Where the contractor mounts the product, he should ensure that the entire area of
the wall to which the mounting plate is to be fitted, is flat (no projecting joints or
tiles sticking out), that the structure of the wall is suitable for the installation of the
product and has no weak points. The enclosed screws and dowels are only suit-
able for concrete. For another wall constructions the manufacturer's indications of
the dowel manufacturer have to be taken into account.
• The filter insert (97708000) must be used to ensure the standard flow rate and
to protect the hand shower against incoming dirt by pipework. Do you want a
larger water flow rate, then you must use the filter packing (94246000) instead
of the filter insert (97708000). Incoming dirt leads to defects or/and can dam-
age parts of the hand shower; such caused faults voids all liability and guarantee
claims.
• The product is not designed to be used with steam baths!
• If the continuous water heater causes any problems, or you have different
water pressures you must install a water limiter to the cold supply, (ordered
separately,article number 97510000).
English
Special accessories
(order as an extra)
tile-matching-disk chrome plated #95163000 (see page 32)
Spare parts
(see page 40)
Cleaning
(see page 37) and enclosed brochure
Operation
(see page 34)
Flow diagram
(see page 37)
Dimensions
(see page 36)
Maintenance
(see page 38)
The check valves must be checked regularly according to DIN EN
1717 in accordance with national or regional regulations (at least once
a year). To guarantee the smooth running of the thermostat, it is neces-
sary from time to time to turn the thermostat from total hot to total cold.
Adjustment
(see page 33)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Safety Function
(see page 33)
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
Do not use silicone containing acetic acid!
Symbol description
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Centre distance:
150±12mm
Connections G 1/2:
cold right - hot left
Thermal disinfection:
max. 70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking water!
Dismounting
(see page 39)
Test certificate
(see page 40)
4