4
Assembly see page 32
Fault
Cause
Remedy
Insufficient water
-
Supply pressure inadequate
-
Check water pressure (If a pump has been installed
check to see if the pump is working).
-
Regulator filter dirty
-
Clean filters
-
Shower filter seal dirty
-
Clean filter seal between shower and hose
Crossflow, hot water being forced into cold water pipe,
or vice versa, when mixer is closed
-
Backflow preventers dirty or leaking
-
Clean backflow preventers, exchange if necessary
Spout temperature does not correspond with tempera-
ture set
-
Thermostat has not been adjusted
-
Adjust thermostat
-
Hot water temperature too low
-
Increase hot water temperature to 42 ºC to 65 ºC
Temperature regulation not possible
-
Temperature regulator dirty or calcified
-
Clean temperature regulator, exchange if necessary
Safety stop button not operating
-
Spring defective
-
Clean spring and/or button, exchange if necessary
-
Button calcified
On/off control stiff
-
On/off control insert defective, calcified
-
Replace on/off control insert
Serviceteile
(see page 35)
Attention, water pipes!
Flow diagram
(see page 39)
4 body s Hand shower
4 body showers
2 body showers
Full-body massage
Hand shower
Dimensions
(see page 31)
Cleaning
(see page 40)
Operation
(see page 38)
Maintenance
(see page 36)
• To guarantee the smooth running of the thermostat, it is necessary
from time to time to turn the thermostat from total hot to total cold.
• The mixer is equipped with check valves. The check valves must be
checked regularly according to DIN EN 1717 in accordance with
national or regional regulations (at least once a year).
Adjustment
(see page 34)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Safety Function
(see page 34)
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
Do not use silicone containing acetic acid!
Symbol description
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The shower system may only be used for bathing, hygienic and body cleansing
purposes.
Children as well as adults with physical, mental and/or sensoric impairments
must not use this shower system without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this shower system.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages.
• The fitting must be installed, flushed and tested after the valid norms!
• The plumbing codes applicable in the respective countries must be oberserved.
• Optimal functioning is only guaranteed with the combination of Hansgrohe hand
showers and Hansgrohe shower hoses.
• Shower hoses are only suitable for a connection from the shower to the fitting.
Never fit a shut-off device between the fitting and the hose.
• During installation of the product by qualified trained personnel, make sure that
the entire fastening surface is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the product and has no weak
points.
• The filter insert must be use to protect the shower against incoming dirt by pipe-
work. Incoming dirt leads to defects or/and can damage parts of the shower;
such caused faults voids all liability and guarantee claims.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,2 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70° C
Recommended hot water temp.:
65° C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
English
Summary of Contents for Raindance Duschpaneel 27009000
Page 32: ...31 380 135 150 Maße ...
Page 34: ...33 1 1 12 13 14 15 16 17 SW 4 mm 5 Nm 2 1 3 2 1 3 2 1 10 ...
Page 35: ...1 2 3 z B 42 C for example 42 C 1 2 3 SaftyFunction max42 34 ...
Page 37: ...7 1 SW 4 mm 1 2 3 4 2 3 4 SW 24 mm SW 24 mm 5 9 SW 24 mm SW 24 mm 6 8 Wartung 36 ...
Page 38: ...13 14 15 16 SW 4 mm 5 Nm 2 1 3 10 2 1 12 2 1 11 17 37 ...