6
7
English
Assembly
The fitting must be installed, flushed and
tested after the valid norms!
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in
position on the basin.
3. Slip the fixation piece including the washer over
the threaded pins and tighten the nuts.
4. Connect the supply pipes to the isolation valves;
cold right - hot left.
5. Connect the pull rod to the pop-up waste.
The hot and cold water supply’s should be of equal
pressures.
Operation
The mixer is activated by lifting the lever handle.
Move to the left = hot water,
move to the right = cold water.
Technical Data
This mixer series-produced with waterdim-
mer (flow limiter)
Rate of flow with waterdimmer: 7 l/min 3 bars
Rate of flow without waterdimmer: 14 l/min 3
bars
Operating pressure: max. 10 bars
Recommended operating pressure: 1 - 5 bars
Test pressure: 16 bars
Hot water temperature: max. 80° C
Recommended hot water temp.: 65° C
Hansgrohe single lever mixers can be used toge-
ther with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 1.5 bars.
If the continuous water heater causes any problems
or there is not enough flow of water, the waterdimmer
(5a) located behind the aerator must be removed.
To adjust the hot water limiter on single lever mixers,
please see page 13.
No adjustment is necessary when using a continuous
flow water heater.
Spare parts
(see page 3)
1 handle
96602000
1.1 screw cover
96338000
2 flange
94192000
3 nut
94194000
4 cartridge cpl.
92730000
5 aerator cpl. (10)
13085000
6 pop up rod
92620000
7 fixing set
96016000
8 connection hose
97206000
Special accessories
X special tool set
58085000
(not part of delivery)