Hans Grohe Metris S 31063XX1 Installation Instructions / Warranty Download Page 8

8

Replacement Parts

1  handle - hot 

97503XX0

 

handle - cold 

97502XX0 

2  valve set 

97960001

3  hot cartridge 

94009000

4  cold cartridge 

94008000

5  connection hose 

94071001

6  3/8" compression ftg  88513000

7  aerator 

13085000

8  pull rod 

96657XX0

9  spout mounting kit 

13961000

10  spout 

97504XX0

11  spout escutcheon 

97505XX0

12  o-ring 11 x 2 

98127000

13  bidet spout 

97506XX0

14  aerator 

97360XX0

15  ball joint 

97362XX0

16  aerator 

94010XX0

17  handle, hot 

95337XX0

18  handle, cold 

95338XX0

19  spout 

95339XX0

XX = finish

00 = chrome

82 = brushed nickel

Metris

1

5

8

9

10

11

4

6

7

12

3

2

14

13

15

Summary of Contents for Metris S 31063XX1

Page 1: ...Installation Instructions Warranty Metris 31063XX1 Metris 31263XX1 Focus 31730001 Talis 32310XX1...

Page 2: ...PSI Recommended incoming water pressure 22 72 PSI Max incoming hot water temp 176 F Recommended incoming hot water temp 120 140 F Max flow rate lavatory faucets 2 2 gpm Max flow rate bidet faucet 2 2...

Page 3: ...wo adhesive strips These strips must be removed before the spout is installed Loosen the spout screw with a 2 5 mm Allen wrench Pull the spout away from the escutcheon Remove the adhesive strips Reass...

Page 4: ...screws Place the handles over the valve mounting nuts Tighten the handles by rotating the escutcheons clockwise The handles should be parallel to the basin If necessary loosen the tensioning screws an...

Page 5: ...ect the hoses to the valve outlets Use two wrenches so that the hoses do not twist or become loosened from the spout tee Screw the connecting hoses into the spout tee Install the supply lines not incl...

Page 6: ...the tee and tailpiece to the flange The pivot must face the faucet If necessary turn the drain assembly Tighten the retainer nut Place the plunger assembly in the drain Install the horizontal rod so...

Page 7: ...ndle forward clockwise to turn the cold water on Turn the handle back counter clockwise to turn the cold water off Turn the left handle forward counter clockwise to turn the hot water on Turn it back...

Page 8: ...88513000 7 aerator 13085000 8 pull rod 96657XX0 9 spout mounting kit 13961000 10 spout 97504XX0 11 spout escutcheon 97505XX0 12 o ring 11 x 2 98127000 13 bidet spout 97506XX0 14 aerator 97360XX0 15 ba...

Page 9: ...Talis Focus 7 12 2 2 12 8 9 11 5 6 3 4 5 6 3 8 11 4 16 17 18 19 9...

Page 10: ...to comply with the needs of the market with regard to design and functionality To avoid damage and returns it is necessary to consider certain criteria when cleaning Cleaning Materials for Faucets and...

Page 11: ...he defective part postage prepaid and carefully packed and insured to Hansgrohe Inc 1492 Bluegrass Lakes Parkway Alpharetta Georgia 30004 Attention Technical Service if required by Hansgrohe When warr...

Page 12: ...Hansgrohe Inc 1490 Bluegrass Lakes Parkway Alpharetta GA 30004 Tel 770 360 9880 Fax 770 360 9887 www hansgrohe usa com US Installation Instructions Part No 90597301 Revised 10 2008...