Assembly see page 32
Fault
Cause
Remedy
Insufficient water
- Shower filter seal dirty
- Clean filter seal between shower
and hose
- Non return valve hasn't moved
back
- Exchange non return valves
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Instantaneous heater didn’t work
- Flow limiter in handshower isn’t
removed
- Remove flow limiter
- Filters are dirty
- Clean the filter / exchange filter
- Non return valve hasn't moved
back
- Exchange non return valves
Test certificate
(see page 40)
Cleaning
(see enclosed brochure)
Operation
(see page 31)
Spare parts
(see page 36)
XXX = Colors
000 = chrome plated
820 = brushed nickel
Flow diagram
(see page 34)
Dimensions
(see page 34)
Do not use silicone containing acetic acid!
Maintenance
(see page 39)
The non return valves must be checked
regularly according to DIN EN 1717
in accordance with national or regional
regulations (at least once a year).
To adjust the hot water limiter on single lever
mixers, please see page 38. No adjustment
is necessary when using a continuous flow
water heater.
Symbol description
6
Safety Notes
6
Gloves should be worn during installation to prevent
crushing and cutting injuries.
6
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6
The hot and cold supplies must be of equal pressu-
res.
Installation Instructions
• The fitting must be installed, flushed and tested after
the valid norms.
• Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous
flow heaters if the flow pressure is at least 0,15 MPa.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Centre distance:
150 ±12 mm
Connections G 1/2:
cold right - hot left
anti-pollution function
English