SafetyNotes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
With water heaters of 5 liters the flow rate at the
mixer should not exceed 5 l/min. In this case the
flow rate must be reduced at the isolation valve.
InstallationInstructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
TechnicalData
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Rate of flow:
max. 5 l/min
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
Safety against backflow
English
Do not use silicone containing acetic acid!
Cleaning
(see enclosed brochure)
Assemblyseepage31
Spareparts
(see page 36)
Fault
Cause
Remedy
Insufficient water
-
Spray former calcified, dirty
-
Clean spray former, exchanging if
necessary
-
Filter at the isolation valves soils.
-
Clean the filter / exchange filter
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping constantly with water
heater switched off
-
Cartridge defective
-
Exchange cartridge
Water escaping in area of swivel
spout
-
O-ring defective
-
Exchange O-ring
Water escaping at the threaded base
-
O-ring at the connection hose defec-
tive.
-
Exchange O-ring
-
Adapter floor leaks
-
Check the adapter floor, replace if
necessary
Water escaping bels ow handle
-
Cartridge defective
-
Exchange cartridge
Dimensions
(see page 35)
Symboldescription
Operation
(see page 34)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
When the storage tank is being heated, the
spout will drip.
Maintenance
(see page 33)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
When changing the spray former, it is
imperative to use one made for this type of
mixer.
4
Testcertificate
(see page 40)
Summary of Contents for Logis 71831000
Page 31: ...31 SW 13 mm 8 Nm 1b SW 10 mm SW 19 mm 8 Nm 3 Nm 1a 2 3 4 5...
Page 33: ...33 SW 10 mm SW 19 mm SW 10 mm SW 19 mm 8 Nm SW 13 mm SW 13 mm 8 Nm 1 1 2 2 1 2 3 4 5...
Page 35: ...35 Logis 71831000 8 5 5 m a x 6 0 34 47 G 3 8 G 3 8 8 51 15 7 202 116 16 194 360...
Page 37: ...37...
Page 38: ...38...
Page 39: ...39...