Assembly see page 31
Cleaning
(see enclosed brochure)
Maintenance non return valve
(see page 36)
The non return valves must be checked
regularly according to DIN EN 1717
in accordance with national or regional
regulations (at least once a year).
Operation
(see page 35)
Spare parts
(see page 34)
Flow diagram
(see page 33)
Dimensions
(see page 33)
Adjustment
(see page 32)
To adjust the hot water limiter on single lever
mixers, please see page 32. No adjustment
is necessary when using a continuous flow
water heater.
Do not use silicone containing acetic acid!
Symbol description
6
Safety Notes
6
Gloves should be worn during installation to prevent
crushing and cutting injuries.
6
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• The fitting must be installed, flushed and tested after
the valid norms.
• Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous
flow heaters if the flow pressure is at least 0,15 MPa.
• There must be an access door for maintenace.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
anti-pollution function
English
4