The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional regula-
tions (at least once a year).
Cleaning
(see page 35) and en-
closed brochure.
Operation
(see page 34)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Flow diagram
(see page 33)
Rate of flow Normal spray
Handspray flow rate
Dimensions
(see page 33)
Do not use silicone containing acetic acid!
Symbol description
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
• Hansgrohe mixers can be used together with hydrauli-
cally and thermically controlled continuous flow heat-
ers if the flow pressure is at least 0,15 MPa.
• The product is exclusively designed for drinking water!