74
Safety and Important Information
Hansgrohe products are safe provided they are in-
stalled, used and maintained in accordance with these
instructions and recornrnendations.
Please read these instructions thoroughly and retain for
future use.
The plumbing installation of this thermostat mixing valve-
must comply with the requirements of UK
Water Regulations/Bylaws (Scotland), Building Regula-
tions or any other regulations specified by the local
Water Authority and supplier.
The installation of thermostatic mixing valves must com-
ply with the requirements of the Water Supply (Water
Fittings) Regulations 1999.
We strongly recommend that you use a plumber regis-
tered with or a member of an Association:
Chartered Institute of Plumbing and Heating Engineer-
ing (CIPHE)
Water Industry Approved Plumber Scheme (WIAPS)
Dispose of plastic bags carefully
Keep children well away from the work area.
Check for hidden pipes and cables in the wall before
drilling holes.
The unit must be mounted on a finished waterproofed
wall surface (usually tiles).
If you are using power tools (e.g. to drill holes) wear
safety glasses and always disconnect tools from the
power supply after use.
Do not operate the shower unit if the hand shower or
spray hose has been damaged or is blocked.
Do not block the flow of water from the hand shower,
by placing it on your hand or any other part of your
body or foreign object.
The thermostatic unit should be serviced annually by a
qualified person to ensure maximum safety during use.
The thermostatic mixing valve will be installed in such
a position that maintenance of the TMV and its valves
and the commissioning and testing of the TMV can be
undertaken.
The mixer is fitted with check valves (page 72 pos.
92594000 / 97350000). There are filters on the ther-
mostatic element too (page 72 pos. 98282000).
The fitting of isolation valves is required (preferred loca-
tion page 75 Installation Requirements)
Technical Hotline
(for UK only)
Tel: 01372465655
Email: [email protected]
(Diese Servicehotline ist nur für das Vereinigte Königre-
ich Großbritannien, nicht z. B. für Deutschland)
Technical Data
This thermostatic valve will suit supplies of:
HIGH PRESSURE (HP-S)
Operating pressure:
max. 10 bar
Recommended operating pressure:
1 - 5 bar
Test pressure:
16 bar
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Rate of flow:
26 l/min. @ 3 bar
Maximum outlet temperature:
43°C +/-*
Safety check:
40°C
Hot water connection:
Left hand
Cold water connection:
Right hand
Minimum difference between hot
water and mixed water temperature:
6 K
Hot and cold supply pressure should be balanced
Mixed water temperature
Application
Mixed water temperature
(at point of discharge).
Shower
41°C max.
Washbasin
41°C max.
Bath (44°C fill)
44°C max.
Bath (46°C fill)
46°C max.
*For preset outlet temperature adjustment –
See page 64.
NB.
If a water supply is fed by gravity then the supply
pressure should be verified to ensure the conditions of
use are appropriate for the valve. Valves operating out-
side of these supply conditions cannot be guaranteed to
operate as a TMV2 or TMV3 valve.
Recommended outlet temperatures
The BuildCert TMV scheme recommends the following
set maximum mixed water outlet temperatures for use in
all premises:
44°C for bath fill but see notes below;
41°C for showers;
41°C for washbasins.
The mixed water temperatures must never exceed
46°C.
On the following pages 74 - 77 you can find important
information only for the installation in UK
Summary of Contents for Ecostat Square 15714700
Page 1: ...Hansgrohe Ecostat Square 15714700...
Page 6: ......
Page 12: ......
Page 18: ......
Page 24: ......
Page 30: ......
Page 31: ...25 62 42 C 60 C 180 180...
Page 33: ...27 62 42 60 180...
Page 36: ......
Page 42: ......
Page 48: ......
Page 50: ...41 62 42 C 60 C 180 180...
Page 54: ......
Page 60: ......
Page 64: ...53 62 42 C 60 C 180 180...
Page 66: ......
Page 68: ...56 62 42 60 180 180...
Page 72: ......
Page 74: ...61 62 1 42 C 60 C 180 Safety Stop...
Page 75: ...62 2 3 1 SW 5 mm Silicone SW 4 mm 5 Nm 3 1 2 5 X 11 2 1 4 X 1 2 mm 0180018X 1...
Page 77: ...64 1 2 3 z B 42 C for example 42 C 2 3 2 SW 3 mm 2 1 2 1 3 2 4 1...
Page 78: ......
Page 79: ...65 2 2 2 7 8 SW 3 mm 1 Nm 2 9a 2 1 5 6 1 2 40 C 2 9b 15708XXX 15758XXX 15714XXX...
Page 80: ...66 2 3 4 5 SW 4 mm 2 2 2 1 2 1 SW 3 mm 6...
Page 82: ...68 2 2 15 40 C 2 16 2 1 13 40 C 2 14 SW 3 mm 1 5 Nm...
Page 84: ......
Page 90: ......
Page 95: ...79...
Page 96: ......
Page 98: ......