Fault
Cause
Remedy
Insufficient water
-
Supply pressure inadequate
-
Check water pressure (If a pump
has been installed check to see if
the pump is working).
-
Regulator filter dirty
-
Clean filter in front of the mixer
and on the MTC-thermo cartridge
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
-
Backflow preventers dirty or leaking
-
Clean backflow preventers, ex-
change if necessary
Spout temperature does not cor-
respond with temperature set
-
Thermostat has not been adjusted
-
Adjust thermostat
-
Hot water temperature too low
-
Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible
-
Temperature regulator dirty or calci-
fied
-
Clean temperature regulator, ex-
change if necessary
-
For new installations: basic body in-
correctly connected (should be: cold
right, hot left) or installed with 180º
rotation
-
Install function block turned
through 180º
Safety stop button not operating
-
Spring defective
-
Clean spring and/or button, ex-
change if necessary
-
push button calcified / contaminated
Valve stiff
-
Shut-off unit damaged
-
Exchange shut-off unit
Shower or spout dripping
-
Dirt or sedimentation on valve seat,
shut-off unit damaged
-
Clean or exchange shut-off unit
Assembly see page 60
Cleaning
see enclosed brochure
Special information for UK
(see page 70)
7
Summary of Contents for Ecostat S
Page 4: ...60 Montage 3 2 4 1 2 1 2 1 2 6 5 X X 11 1 2 mm...
Page 6: ...62 Safety Function Justierung 1 2 S W 3 m m 1 2 3...
Page 7: ...63 Safety Function 2 1 5 6 S W 3 m m 4 N m 7 8 z B 42 C for example 42 C 1 2 3 4 SW 2 mm 4 Nm...
Page 8: ...64 Wartung SW 4 mm 1 2 2 3 4 5 6 SW 24 mm 1 2 3 1 S W 3 m m SW 2 mm 4...