7
English
Assembly
(see page 60)
Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Regulator filter dirty
- Clean filter in front of the mixer
and on the MTC-thermo cartridge
- Shower filter seal dirty
- filter insert shower dirty
- Clean filter seal between shower
and hose
- Clean filter insert between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
- Backflow preventers dirty or
leaking
- Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
- Thermostat has not been adjusted
- Adjust thermostat
- Hot water temperature too low
- Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible - thermo cartridge calcified
- Exchange thermo cartridge
- For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180º rotation
- Install function block turned
through 180º
Safety stop button not operating
- Spring defective
- Button calcified
- Clean spring and/or button,
exchange if necessary
Valve stiff
- Shut-off unit damaged
- Exchange shut-off unit
Shower or spout dripping
- Dirt or sedimentation on valve seat,
shut-off unit damaged
- Clean or exchange shut-off unit
Summary of Contents for Ecostat S 15757 Series
Page 25: ...25 60 42 C 65 C 180 180...
Page 27: ...27 60 42 65 180...
Page 41: ...41 60 42 C 65 C 180 180...
Page 53: ...53 60 42 C 65 C 180 180...
Page 56: ...56 60 42 65 180 180...
Page 60: ...60 2 3 1 SW 4 mm 5 Nm X 11 X 1 2 mm 01800180 2 1 silicone 1 2 3 4 5...
Page 61: ...61 40 C 40 C 40 C 40 C 2 0 1 Nm 40 C SW 3 mm 4 Nm 1 2 1 6 7 8 9 10...
Page 64: ...64 40 C 40 C 40 C z B 42 C for example 42 C 40 C 3 2 SW 3 mm 2 1 40 C 1 1 2 3 4 1 2 3...
Page 66: ...66 40 C 40 C SW 4 mm 40 C 40 C 40 C 2 1 SW 3 mm 1 2 3 4 5 6...
Page 68: ...68 40 C 40 C 40 C 40 C 2 1 40 C 40 C SW 3 mm 4 Nm 13 14 15 16...