Assembly see page 60
Fault
Cause
Remedy
Insufficient water
-
Supply pressure inadequate
-
Check water pressure (If a pump
has been installed check to see if
the pump is working).
-
Regulator filter dirty
-
Clean filter in front of the mixer and
on the MTC-thermo cartridge
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
-
Backflow preventers dirty or
leaking
-
Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
-
Thermostat has not been adjusted
-
Adjust thermostat
-
Hot water temperature too low
-
Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible
-
Temperature regulator dirty or
calcified
-
Clean temperature regulator,
exchange if necessary
-
For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180º rotation
-
Install function block turned through
180º
Safety stop button not operating
-
Spring defective
-
Button calcified
-
Clean spring and/or button,
exchange if necessary
Valve stiff
-
Shut-off unit damaged
-
Exchange shut-off unit
Shower or spout dripping
-
Dirt or sedimentation on valve seat,
shut-off unit damaged
-
Clean or exchange shut-off unit
English
Special information for UK
(see page 69)
7
Summary of Contents for Ecostat E 15700000
Page 25: ...60 MTC 42 C 65 C 180 180 25...
Page 27: ...60 42 65 180 27...
Page 43: ...60 42 C 65 C 180 180 43...
Page 55: ...60 42 C 65 C 180 180 55...
Page 58: ...60 42 65 180 180 58...
Page 60: ...60 3 2 4 6 5 1 2 1 2...
Page 62: ...62 1 1a 1b 2 3a 3b 1c 1d SW 2 mm SW 2 mm SW 3 mm...
Page 63: ...63 2 1 SW 3 mm 4 Nm z B 42 C for example 42 C 1 2 6 2 4 3 5 7a 7b SW 2 mm 4 Nm SW 2 mm 4 Nm...
Page 67: ...67 Ecostat E 15700000 Ecostat S 15701000 PuraVida15775XXX Metris 31572000...
Page 75: ...75...