Hans Grohe EcoSmart 31632000 Instructions For Use Manual Download Page 4

  Assembly 

(see page 11)

 

Safety Notes

 

Gloves should be worn during installation to prevent 
crushing and cutting injuries.

 

The product may only be used for bathing, hygienic 
and body cleaning purposes.

 

The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 
surface damage will be honoured.

• The pipes and the fixture must be installed, flushed 

and tested as per the applicable standards.

• The plumbing codes applicable in the respective 

countries must be observed.

• The drain valve must only be used as intended. It is not 

allowed to attach other objects to the drain valve, for 
example a semi-pedestal.

• The drain valve may only be installed in basins with 

an overflow opening.

• If the instantaneous water heater causes  problems or 

if you wish to increase the water flow, the EcoSmart

®

 

(flow limiter) located behind the aerator can be 
removed.

Technical Data

This mixer series-produced with EcoSmart

®

 

(flow limiter)

Operating pressure: 

max. 1 MPa

Recommended operating pressure: 

0,1 - 0,5 MPa

Test pressure: 

1,6 MPa

 

(1 MPa = 10 bar = 147 PSI)

Hot water temperature: 

max. 70°C

Recommended hot water temp.: 

65°C

Thermal disinfection 

max. 70°C / 4 min

The product is exclusively designed for drinking water!

English

Cleaning 

(see page 16)

Flow diagram 

(see page 13)

  with EcoSmart

®

  without EcoSmart

®

Dimensions 

(see page 13)

Spare parts 

(see page 15)

Test certificate 

(see page 16)

Do not use silicone containing acetic acid!

Symbol description

Operation 

(see page 14)

Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn 
in the morning or after a prolonged period 
of non-use.

Adjustment 

(see page 12)

To adjust the hot water limiter. Using a hot 
water limiter in combination with a continu-
ous flow water heater is not recommended.

4

Summary of Contents for EcoSmart 31632000

Page 1: ...ctions for use assembly instructions 4 IT Istruzioni per l uso Istruzioni per Installazione 5 ES Modo de empleo Instrucciones de montaje 6 NL Gebruiksaanwijzing Handleiding 7 DK Brugsanvisning Monteri...

Page 2: ...becken mit ber lauf eingesetzt werden Bei Problemen mit dem Durchlauferhitzer oder wenn mehr Wasserdurchsatz gew nscht wird kann der EcoSmart Durchflussbegrenzer der hinter dem Luftsprudler sitzt entf...

Page 3: ...robl mes avec le chauffe eau ou bien si le d bit d eau doit tre plus important il est possible d enlever l EcoSmart limiteur de d bit se trouvant derri re l a rateur Informations techniques Robinetter...

Page 4: ...ter heater causes problems or if you wish to increase the water flow the EcoSmart flow limiter located behind the aerator can be removed Technical Data This mixer series produced with EcoSmart flow li...

Page 5: ...in lavandini con sfioratore Nel caso di problemi con lo scalda acqua oppure nel caso si desiderasse pi erogazione si pu eliminare il EcoSmart limitatore di flusso che si trova dietro la valvola di ae...

Page 6: ...rebose En caso de problemas con el calentador instant neo o cuando se desee m s caudal de agua puede quitar se el EcoSmart limitador de caudal situado detr s del aireador Datos t cnicos Grifo desde f...

Page 7: ...leen in wastafels met over loop geplaatst worden Wanneer problemen optreden bij doorloopgeisers of wanneer een grotere waterdoorvoer gewenst is kan de EcoSmart doorstroombegrenzer die achter de perlat...

Page 8: ...problemer med genneml bsvandvarmer eller hvis der nskes mere vandgennemstr mning kan EcoS mart gennemstr mningsbegr nseren der sidder i perlatoren fjernes Tekniske data Armaturet er forsynet med EcoS...

Page 9: ...ywowymi pod grzewaczami wody lub je li chce si uzyska wi kszy przep yw wody mo na usun EcoSmart ogranicz nik przep ywu znajduj cy si za napowietrzaczem Dane techniczne Armatura produkowana seryjnie z...

Page 10: ...11 EcoSmart EcoSmart 1 0 1 0 5 1 6 1 10 bar 147 PSI 70 C 65 C 70 C 4 16 13 C EcoSmart EcoSmart 13 15 16 14 Hansgrohe 12 10...

Page 11: ...11 Montage 1 2 1 2 7 Nm 5 6 SW 22 mm 2 min 7 SW 22 mm 2 Nm 3 4 SW 9 mm SW 19 mm 4 Nm...

Page 12: ...0 3 MPa 0 3 0 3 60 C 10 C 0 3 MPa 0 3 2 1 3 4 5 6 7 4 3 1 2 3 1 2 6 x 36 C 38 C 43 C 50 C 55 C 60 C 17 x S W 4 m m S W 4 m m 5 N m SW 4 mm SW 4 mm 12 Justierung...

Page 13: ...13 Durchflussdiagramm Ma e Talis Puro 31632000 31633000 Talis Puro 31633000 Talis Puro 31632000 50100000 EcoSmart EcoSmart 1 2...

Page 14: ...ienung ffnen ouvert open aperto abierto open bne otworzy schlie en ferm close chiudere cerrar sluiten lukke zamkn warm chaud hot caldo caliente warm varmt ciep a kalt froid cold freddo fr o koud koldt...

Page 15: ...338000 97406000 97209000 M37x1 5 SW 30 mm 95140000 M4x20 SW 4 mm 95008000 13085000 M24x1 7 l min SW 22 mm 97608000 97206000 450 mm 96016000 SW 11 mm 92730000 98154000 32x2 98186000 30x2 98750000 50100...

Page 16: ...ies Contact EN Cleaning recommendation Warranty Contact IT Raccomandazione di pulizia Garanzia Contatto ES Recomendaciones para la limpieza Garant a Contacto NL Aanbevelingen inzake reiniging Garantie...

Reviews: