Assembly see page 6 

Fault

Cause

Remedy

Insufficient water

- Supply pressure inadequate

- Check water pressure (If a pump 

has been installed check to see if 
the pump is working).

- Filters are dirty (96922000)

- Clean filter in front of the mixer 

and on the BTC-thermo cartridge 
(96922000)

- Shower filter seal dirty

- Clean filter seal between shower 

and hose

- Backflow preventers dirty or leak-

ing

- Clean backflow preventers, ex-

change if necessary

Crossflow, hot water being forced 
into cold water pipe, or vice versa, 
when mixer is closed

- Backflow preventers dirty or leak-

ing

- Clean backflow preventers, ex-

change if necessary

Spout temperature does not cor-
respond with temperature set

- Thermostat has not been adjusted 

Hot water temperature too low

- Adjust thermostat 

Increase hot water temperature to 
42 ºC to 65 ºC

Temperature regulation not possible

- thermo cartridge calcified

- Exchange thermo cartridge

Shower or spout dripping

- Dirt or sedimentation on valve seat, 

shut-off unit damaged

- Clean or exchange shut-off unit

Instantaneous heater didn't work 
with thermostat

- Flow limiter in handshower isn’t 

removed

- Remove flow limiter

- Filters are dirty

- Clean the filter / exchange filter

- Non return valve hasn't moved 

back

- Exchange non return valves

Test certificate 

(see page 12)

Cleaning 

(see page 13)

Spare parts 

(see page 12)

Dimensions 

(see page 11)

Operation 

(see page 9)

English

Special information for UK 

(see page 14)

3

Summary of Contents for Ecomax 14243000

Page 1: ...EN Instructions for use assembly instructions 2 DE Gebrauchsanleitung Montageanleitung 4 Ecomax 14243000...

Page 2: ...utting injuries The shower system may only be used for bathing hygienic and body cleansing purposes Children as well as adults with physical mental and or sensoric impairments must not use this shower...

Page 3: ...necessary Spout temperature does not cor respond with temperature set Thermostat has not been adjusted Hot water temperature too low Adjust thermostat Increase hot water temperature to 42 C to 65 C T...

Page 4: ...r Trinkwasser konzi piert Sicherheitshinweise Bei der Montage m ssen zur Vermeidung von Quetsch und Schnittverletzungen Handschuhe getragen werden Das Produkt darf nur zu Bade Hygiene und K rper reini...

Page 5: ...r stimmt nicht mit der eingestellten Temperatur berein Thermostat wurde nicht justiert Zu niedrige Warmwassertempe ratur Thermostat justieren Warmwassertemperatur erh hen auf 42 C bis 65 C Temperaturr...

Page 6: ...6 SW 30 mm 17 Nm SW 30 mm 17 Nm 2b 1 2a...

Page 7: ...7 SW 3 mm 2 Nm SW 3 mm 42 40 1 2 3 4 5 6...

Page 8: ...8 1 2 3...

Page 9: ...9 close schlie en 90 open ffnen 1 2 cold kalt 40 C hot warm 90...

Page 10: ...10 SW 30 mm SW 12 mm 2 1 2 3 4 1...

Page 11: ...11 Ecomax 14243000...

Page 12: ...12 96922000 97210000 97163000 97164000 98870000 95589000 92929000 96488000 97211000 98163000 15x2 98194000 28x2 96644000 A 96633000 Ecomax 14243000 PA IX DVGW SVGW ACS WRAS ETA KIWA 14243000 X...

Page 13: ...g recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation EN Cleaning recommendation Warranty Contact DE Reinigungs...

Page 14: ...waterproofed wall surface usually tiles If you are using power tools e g to drill holes wear sa fety glasses and always disconnect tools from the power supply after use Do not operate the shower unit...

Page 15: ...allowable temperature tolerances inherent in thermo static mixing valves and temperature losses in metal baths It is not a safe bathing temperature for adults or children The British Burns Association...

Page 16: ...16 KEY Isolating valve Reducing valve Mixer Valve Pump Gas Combination Boiler multi point Unvented System pressure balanced Pumped System...

Page 17: ...priate at commissioning to carry out some simple checks and tests on each mixing valve to provide a performance reference point for future in service tests Procedure 1 Check that a the designation of...

Page 18: ...ce of any other instruction or guidance on the means of determining the appropriate frequency of in service testing the following procedure may be used 1 6 to 8 weeks after commissioning carry out the...

Page 19: ...after correct installation the outlet temperature of the water can never exceed 43 C To guarantee a smooth running of the thermostatic element it is necessary from time to time to turn the thermostat...

Page 20: ...20 Hansgrohe Auestra e 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 08 2018 9 04410 04...

Reviews: