Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Filters are dirty (96922000)
- Clean filter in front of the mixer
and on the BTC-thermo cartridge
(96922000)
- Shower filter seal dirty
- Clean filter seal between shower
and hose
- Backflow preventers dirty or leak-
ing
- Clean backflow preventers, ex-
change if necessary
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
- Backflow preventers dirty or leak-
ing
- Clean backflow preventers, ex-
change if necessary
Spout temperature does not cor-
respond with temperature set
- Thermostat has not been adjusted
Hot water temperature too low
- Adjust thermostat
Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible
- thermo cartridge calcified
- Exchange thermo cartridge
Shower or spout dripping
- Dirt or sedimentation on valve seat,
shut-off unit damaged
- Clean or exchange shut-off unit
Instantaneous heater didn't work
with thermostat
- Flow limiter in handshower isn’t
removed
- Remove flow limiter
- Filters are dirty
- Clean the filter / exchange filter
- Non return valve hasn't moved
back
- Exchange non return valves