Maintenance
(see page 8)
• To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot
to total cold.
• The mixer is equipped with non return
valves.
The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
At this time, please also check the filter
(A) situated on the BTC-thermoelement
(96633000). After assembling the BTC-
thermoelement, it is necessary to check
the water temperature at the take off
point as described under the headline
„adjustment“. Before the adjustment,
please check, if the warm water supply is
activated and the maximum temperature
of the warm water is available at the take
off point.
Adjustment
(see page 7)
After the installation, the output tempera-
ture of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
Do not use silicone containing acetic acid!
Symbol description
• Anti-pollution function
• The product is exclusively designed for drinking water!
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages.
After it has been installed, no transport or surface
damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms!
• The plumbing codes applicable in the respective
countries must be oberserved.
• The product is not designed to be used with steam
baths!
Thermostatic mixer in conjunction with
combination boilers
• If fitting a hand shower remove the water limiter from
the shower.
• If the continuous water heater causes any problems,
or you have different water pressures you must
install a water limiter to the cold supply, (ordered
separately,article number 97510000).
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max.70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
Rate of flow Bath Spout:
58 l/min 0,3 MPa
Rate of flow Shower outlet:
18 l/min 0,3 MPa