Hansgrohe products are safe provided they are installed, 
used and maintained in accordance with these instructions 
and recornrnendations.

Please  read  these  instructions  thoroughly  and  retain  for 
future use.

The plumbing installation of this thermostat mixing valvemust 
comply with the requirements of UK
Water Regulations/Bylaws (Scotland), Building Regulati-
ons or any other regulations specified by the local Water 
Authority and supplier.

The installation of thermostatic mixing valves must comply 
with the requirements of the Water Supply (Water Fittings) 
Regulations 1999.

We strongly recommend that you use a plumber registered 
with or a member of an Association:

Chartered Institute of Plumbing and Heating Engineering 
(CIPHE)
Water Industry Approved Plumber Scheme (WIAPS)

Dispose of plastic bags carefully

Keep children well away from the work area.

Check  for  hidden  pipes  and  cables  in  the  wall  before 
drilling holes.

The unit must be mounted on a finished waterproofed wall 
surface (usually tiles).

If you are using power tools (e.g. to drill holes) wear sa-
fety glasses and always disconnect tools from the power 
supply after use.

Do not operate the shower unit if the hand shower or spray 
hose has been damaged or is blocked.

Do not block the flow of water from the hand shower, by 
placing it on your hand or any other part of your body or 
foreign object.

The  thermostatic  unit  should  be  serviced  annually  by  a 
qualified person to ensure maximum safety during use.

The thermostatic mixing valve will be installed in such a 
position that maintenance of the TMV and its valves and the 
commissioning and testing of the TMV can be undertaken.

The  mixer  is  fitted  with  check  valves  (page  14  pos. 
96644000). There are filters on the thermostatic element 
too (page 14 pos. A and 96922000).

The fitting of isolation valves is required (preferred location 
page 17 Installation Requirements)

Onthefollowingpages16-21youcan

findimportantinformationonlyforthe

installationinUK

TechnicalHotlineforUKonly

01372465655

E-mailforUKonly

[email protected]

(Diese Servicehotline ist nur für das Vereinigte König-
reich Großbritannien, nicht z. B. für Deutschland)

Summary of Contents for Ecomax 13354000

Page 1: ...DE Gebrauchsanleitung Montageanleitung 2 EN Instructions for use assembly instructions 4 Ecomax 13356000 Ecomax 13354000...

Page 2: ...optional erh ltliche Drossel Artikelnummer 97510000 in den Kaltwasser zulauf eingesetzt werden Technische Daten Betriebsdruck max 1 MPa Empfohlener Betriebsdruck 0 1 0 5 MPa Pr fdruck 1 6 MPa 1 MPa 1...

Page 3: ...ckflussverhinderer reinigen ggf austauschen Auslauftemperatur stimmt nicht mit der eingestellten Temperatur berein Thermostat wurde nicht justiert Thermostat justieren Zu niedrige Warmwassertemperatu...

Page 4: ...install a water limiter to the cold supply ordered separately article number 97510000 Technical Data Operating pressure max 1 MPa Recommended operating pressure 0 1 0 5 MPa Test pressure 1 6 MPa 1 MP...

Page 5: ...ty or leaking Clean backflow preventers ex change if necessary Spout temperature does not cor respond with temperature set Thermostat has not been adjusted Adjust thermostat Hot water temperature too...

Page 6: ...6 X X 36 mm X 36 1 3b 2 3a 1 2 1 2 Silicone max 39 mm max 5 mm 1 2 5 4 36 mm SW 24 mm...

Page 7: ...7 6 7 8 SW 30 mm 17 Nm...

Page 8: ...8 Ecomax 13354000 Ecomax 13356000 R 1 2 R 1 2 P IX DVGW SVGW ACS WRAS ETA KIWA 13354000 X 13356000 X...

Page 9: ...9 SW 3 mm SW 3 mm 2 Nm 1 3 4 2 5 6...

Page 10: ...10 z B 42 C for example 42 C 4 3 1 2 5 1 2 S W 3 m m S W 3 m m 2 N m...

Page 11: ...11 5 6 SW 30 mm SW 30 mm 17 Nm SW 12 mm SW 12 mm 20 Nm 4 1 1 2 2 3 1 2 SW 24 mm 1 2 SW 24 mm 20 Nm 1 2...

Page 12: ...12 1 2 3...

Page 13: ...13 schlie en close 90 ffnen open 1 2 kalt cold 40 C warm hot 90 1 2...

Page 14: ...00 97211000 25x2 97164000 95041000 96633000 98147000 26x2 34x2 38x2 5 A 96264000 97162000 92929000 96264000 Ecomax 13356000 94140000 96429000 98163000 15x2 96157000 96467000 96922000 97220000 96644000...

Page 15: ...terproofed wall surface usually tiles If you are using power tools e g to drill holes wear sa fety glasses and always disconnect tools from the power supply after use Do not operate the shower unit if...

Page 16: ...herent in thermostatic mixing valves and temperature losses in metal baths It is not a safe bathing temperature for adults or children The British Burns Association recommends 37 to 37 5 C as Installa...

Page 17: ...17 KEY Isolating valve Reducing valve Mixer Valve Pump Gas Combination Boiler multi point Unvented System pressure balanced Pumped System...

Page 18: ...me simple checks and tests on each mixing valve to provide a performance reference point for future in service tests Procedure 1 Check that a the designation of the thermostatic mixing valve matches t...

Page 19: ...ce of any other instruction or guidance on the means of determining the appropriate frequency of in service testing the following procedure may be used 1 6 to 8 weeks after commissioning carry out the...

Page 20: ...xer is fitted with check valves page 14 pos 96644000 and filters page 14 pos A and 96922000 If the water flow drops the filters need to be cleaned For that purpose please follow the steps 1 8 on page...

Reviews: