SafetyNotes

 

Gloves should be worn during installation to prevent 
crushing and cutting injuries.

 

The product may only be used for bathing, hygienic 
and body cleaning purposes.

 

The hot and cold supplies must be of equal pres-
sures. 

InstallationInstructions

• Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 
surface damage will be honoured.

• The pipes and the fixture must be installed, flushed 

and tested as per the applicable standards.

• The plumbing codes applicable in the respective 

countries must be observed. 

TechnicalData

Operating pressure: 

max. 1 MPa

Recommended operating pressure: 

0,1 - 0,5 MPa

Test pressure: 

1,6 MPa

(1 MPa = 10 bar = 147 PSI)
Hot water temperature: 

max. 70°C

Recommended hot water temp.: 

65°C

Thermal disinfection: 

max. 70°C / 4 min

The product is exclusively designed for drinking water!

English

Dimensions

(see page 7)

Operation

(see page 6)

Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn 
in the morning or after a prolonged period 
of non-use.

Do not use silicone containing acetic acid!

Flowdiagram

(see page 7)

Spareparts

(see page 8)

Cleaning

(see page 6)

Symboldescription

Assemblyseepage4

Adjustment

(see page 5)

To adjust the hot water limiter. Using a hot 
water limiter in combination with a continu-
ous flow water heater is not recommended.