Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Regulator filter dirty
- Clean filters
- Shower filter seal dirty
- Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
- Backflow preventers dirty or
leaking
- Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
- Thermostat has not been adjusted
- Adjust thermostat
- Hot water temperature too low
- Increase hot water temperature to
42 C to 65 C
Temperature regulation not possible - Temperature regulator dirty or
calcified
- Clean temperature regulator,
exchange if necessary
- For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180 rotation
- Install function block turned through
180
Safety stop button not operating
- Spring defective
- Button calcified
- Clean spring and/or button,
exchange if necessary
Valve stiff
- Shut-off unit damaged
- Exchange shut-off unit
Shower or spout dripping
- Dirt or sedimentation on valve seat,
shut-off unit damaged
- Clean or exchange shut-off unit
English
Summary of Contents for AXOR Urquiola 11422000
Page 1: ...Montageanleitung Urquiola 11422000...
Page 27: ...27 42 C 65 C 180 180...
Page 29: ...29 42 65 180...
Page 45: ...45 temperatura del agua demasiado baja no hay 42 C 65 C 180 180...
Page 47: ...47 42 65 180 180...
Page 59: ...59 42 C 65 C 180 180...
Page 64: ...64 1 2 3 4 Safety Function...