Fault
Cause
Remedy
Insufficient water
-
Supply pressure inadequate
-
Check water pressure (If a pump
has been installed check to see if
the pump is working).
-
Filters are dirty
-
Clean filter in front of the mixer and
on the MTC-thermo cartridge
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
-
Backflow preventers dirty or leaking
-
Clean backflow preventers, ex-
change if necessary
Spout temperature does not cor-
respond with temperature set
-
Thermostat has not been adjusted
-
Adjust thermostat
-
Hot water temperature too low
-
Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible
-
thermo cartridge calcified
-
Exchange thermo cartridge
-
For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180º rotation
-
Install function block turned through
180º
Safety stop button not operating
-
Spring defective
-
Button calcified
-
Clean spring and/or button, ex-
change if necessary
English
Special information for UK
(see page 69)
7
Summary of Contents for AXOR Starck
Page 60: ...60 1 2 mm X 1 2 3 4 6 5 10754180 SW 24 mm 15 Nm SW 27 mm SW 17 mm 1 2 ...
Page 61: ...61 1 2 SW 3 mm 4 Nm 0 1 Nm X 11 11 12 8 7 10 9 1 2 SW 2 mm 4 Nm 3 ...
Page 62: ...62 1 2 1 3 2 SW 2 mm 4 Nm SW 2 mm SW 2 mm 2 2 2 2 1 1 1 1 SW 3 mm ...
Page 63: ...63 4 3 6 5 7 8 2 2 2 2 1 1 1 1 SW 3 mm 4 Nm SW 2 mm 4 Nm ...
Page 64: ...64 2 3 4 1 6 5 SW 24 mm SW 2 mm SW 3 mm 1 2 3 ...
Page 65: ...65 8 9 10 7 11 SW 2 mm 4 Nm SW 3 mm 4 Nm SW 24 mm 15 Nm 1 2 3 ...
Page 66: ...66 40 C 1 2 ...
Page 67: ...67 Starck 10755000 Citterio E 36702000 120 120 12 57 85 Ø49 ...
Page 75: ...75 ...