Maintenance
(see page 64)
• To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot
to total cold.
• The mixer is equipped with non return
valves. The non return valves must be
checked regularly according to DIN
EN 1717 in accordance with national
or regional regulations (at least once
a year). At this time, please also check
the filter (A) situated on the BTC-
thermoelement (96633000). After
assembling the BTC-thermoelement, it is
necessary to check the water temperature
at the take off point as described under
the headline „adjustment“. Before the
adjustment, please check, if the warm
water supply is activated and the
maximum temperature of the warm water
is available at the take off point.
Adjustment
(see page 63)
After the installation, the output temperature
of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
Safety Function
(see page 62)
The desired maximum temperature for
example max. 42º C can be pre-set thanks
to the safety function.
Do not use silicone containing acetic acid!
Symbol description
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms!
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,15 – 0,6 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Rate of flow by 0,3 MPa:
1 Consumer
approx. 44 l/min
2 Consumer
approx. 55 l/min
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
Anti-pollution function
English
6
Summary of Contents for Axor Starck 10755000
Page 25: ...60 42 C 65 C 180 68 66 67 68 25...
Page 27: ...60 42 65 180 68 66 67 68 27...
Page 43: ...60 42 C 65 C 180 68 66 67 68 43...
Page 55: ...60 42 C 65 C 180 68 66 67 68 55...
Page 58: ...60 42 65 180 68 66 67 68 58...
Page 60: ...60 27 mm 1 2 3 4 Silicon 17 mm 6 5 24 mm 15 2 Nm 10754180...
Page 61: ...61 11 12 8 2 mm 7 3 mm 4 1 Nm 2 1 10 9...
Page 62: ...62 1 2 2 mm 3 mm 1 3 2 1 2 2 mm 2 mm 1 2 4 1 Nm...
Page 63: ...63 4 3 6 1 2 5 3 mm 1 2 7 8 1 2 2 mm 4 1 Nm...
Page 64: ...64 2 3 4 1 1 2 3 6 5 SW 24 mm 3 mm 2 mm...
Page 65: ...65 8 9 10 7 3 11 2 mm 3 mm 4 1 Nm SW 24 mm 15 2 Nm...
Page 66: ...66 1 40 C 2...
Page 68: ...68 PA IX DVGW SVGW ACS WRAS KIWA ETA 10755000 X X X Starck 10755000...