4
Cleaning
see enclosed brochure
Test certificate
(see page 40)
Dimensions
(see page 37)
Operation
(see page 40)
Spare parts
(see page 39)
Flow diagram
(see page 38)
Do not use silicone containing acetic acid!
Symbol description
Safety Notes
• Gloves should be worn during installation to prevent
crushing and cutting injuries.
• The product may only be used for bathing, hygienic
and body cleaning purposes.
• Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this
product.
• The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• It is not permitted to install a shutoff device (f.e. a
single-lever mixer) upstream of the built-in valve for 3
consumers!
• If the thermostat or mixer is set to maximum water
temperature, there is a risk of scalding at hydraulical
opening of the check valve. For this reason, Hansgro-
he recommends that you set up the "Safety Function".
Special information for UK
If installing this product with a pump, please be aware
that it has to have negative head switching. This product
will not function with a positive head pump..
English
Fault
Cause
Remedy
Valve stiff
-
Select stop valve DN9 damaged
-
Exchange Select stop valve DN9
Shower or spout dripping
-
Select stop valve DN9 damaged
-
Exchange Select stop valve DN9
Pushbutton cannot be actuated or is
without function
-
Safety guard of isolating valve has
not been removed
-
Remove safety guard from isolating
valve
Pushbutton is jammed or stiff
-
Seal needs greasing
-
Grease the seal
Pushbutton does not snap in
-
Select Adapter incorrectly trimmed
-
Trim and mount Select Adapter ac-
cording to Fig. 7 (see page 32)
-
First, fully press the pushbutton
down into the rosette; then, mount
the rosette
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
Assembly see page 31
Summary of Contents for AXOR ShowerSelect Square 36717000
Page 31: ...31 01800180 2 1 SW 4 mm 5 Nm 4 1 2 3 2 1 3 2 1 5 SW 4 mm...
Page 32: ...32 9 SW 4 mm 6 8 1 2 7 0 mm 0 mm 1 2 10...
Page 33: ...33 2 mm 4 mm 0 mm 2 mm 11a 11b 12b 12a 1 mm...
Page 34: ...34 14 X 16 13 1 2 mm X 15 16 0 1 Nm 18 1 2 2 1 17...
Page 35: ...35 19 20 21 22 1 2 23 36...
Page 36: ...36 0 max 5 A C B SW 4 mm SW 4 mm 5 Nm 7 mm 1 2...