Assembly
Important!  The  fitting  must  be  installed, 

flushed and tested after the valid norms.

The  hot  and  cold  supplies  must  be  of  equal 

pressures.

Technical Data

Operating pressure: 

max. 1 MPa

Recommended operating pressure:  0,1 - 0,5 MPa

Test pressure: 

1,6 MPa

(1 MPa = 10 bar = 147 PSI)

Hot water temperature: 

max. 80° C

Recommended hot water temperature: 65° C

Centre distance: 

170 ± 44 mm

Connections G  ½: 

cold right

 

 

hot left

Rate of flow by 0,3 MPa: 

approx. 18 l/min

Back flow and vacuum breaker

Hansgrohe  mixers  can  be  used  together  with  hy-

draulically  and  thermically  controlled  continuous 

flow  heaters  if  the  flow  pressure  is  at  least  0,15 

MPa. 

Important!

The  non  return  valves  must  be  checked  regularly 

according  to  DIN  EN  1717  in  accordance  with 

national  or  regional  regulations  (at  least  once  a 

year).

Spare parts

 (see page 3)

handle 

16597XXX

screw cover for cold / hot water  97987000

sleeve 

97993XXX

aerator cpl. M24x1 

98575XXX

shut off unit, 

94009000

non return valve 

94074000

selector 

98591000

noise reduction 

96429000

sliding gear lever 

98594XXX

10  cover cap set 

98593XXX

11  shower base 

98590XXX

12  shower holder 

16320XXX

13  hose 1,25 m  

28112XXX

14  filter packing 

94246000

15  hexagon socket screw M10x35 (set) 97670000

16  supply pipe (set) 

97226000

XXX 

= Colors

000  chrome plated

820  brushed nickel

830  polished nickel

Operation

Hot surface!

Summary of Contents for AXOR Montreux 16547 Series

Page 1: ...Montageanleitung Montreux 16547XXX ...

Page 2: ... DIN 4109 PA IX18729 ICB ...

Page 3: ... 2 1 3 4 5 6 7 8 9 9 10 11 12 13 14 44x2 5 35x2 0 16 15 ...

Page 4: ... 1 2 1 Montage Assembly Montaggio Montaje Montering Montagem Montaż 2 3 4 1 2 3 4 5 ...

Page 5: ...ngesetzt werden wenn der Fließdruck mindestens 0 15 MPa beträgt Achtung Rückflussverhinderer müssen gemäß DIN EN 1717 regelmäßig in Übereinstimmung mit nationalen oder regionalen Bestimmungen DIN 1988 einmal jährlich auf ihre Funktion geprüft werden Deutsch Serviceteile siehe Seite 3 1 Griff 16597XXX 2 Griffstopfen Kalt Warm 97987000 3 Hülse 97993XXX 4 Luftsprudler kpl M24x1 98575XXX 5 Absperreinh...

Page 6: ...que à condition que la pression soit au minimum de 0 15 MPa Attention Les clapets anti retour doivent être examinés ré gulièrement conformément à la norme EN 1717 ou conformément aux dispositions nationales ou régionales quant à leur fonction au moins une fois par an Pièces détachées voir pages 3 1 poignée 16597XXX 2 cache vis eau froide chaude 97987000 3 douille 97993XXX 4 aérateur cpl M24x1 9857...

Page 7: ...ontinuous flow heaters if the flow pressure is at least 0 15 MPa Important The non return valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations at least once a year Spare parts see page 3 1 handle 16597XXX 2 screw cover for cold hot water 97987000 3 sleeve 97993XXX 4 aerator cpl M24x1 98575XXX 5 shut off unit 94009000 6 non return valve 94074...

Page 8: ...essione se la pressione di flus so è almeno di 0 15 MPa Attenzione La valvola di non ritorno deve essere controllata regolarmente come da DIN EN 1717 secondo le normative nazionali e regionali almeno una volta all anno Parti di ricambio vedi pagg 3 1 maniglia 16597XXX 2 tappino acqua fredda calda 97987000 3 canotto 97993XXX 4 rompigetto compl M24x1 98575XXX 5 cartuccia d arresto 94009000 6 valvola...

Page 9: ...manera hidráulica o térmica siempre que la presión del caudal ascienda a un mínimo de 0 15 MPa ATENCION Las válvulas anti retorno tienen que ser controladas regularmente según la norma DIN EN 1717 en acuerdo con las regulaciones nacionales o regionales una vez al año por lo menos Repuestos ver página 3 1 Mando 16597XXX 2 Tapón agua frio caliente 97987000 3 Casquillo 97993XXX 4 Aireador completo M2...

Page 10: ...urde geisers gebruikt worden in dien de uitstroomdruk min 0 15 MPa bedraagt Attentie Keerkleppen moeten volgens DIN EN 1717 regelmatig en volgens plaatselijk geldende eisen op het funktioneren gecontroleerd worden Tenminste een keer per jaar Service onderdelen zie blz 3 1 greep 16597XXX 2 greepstopje koud warm water 97987000 3 huls 97993XXX 4 perlator kompl M24x1 98575XXX 5 bovendeel 94009000 6 te...

Page 11: ...yrede gennemstrøm ningsvandvarmere ved et vandtryk på 0 15 MPa Advarsel Ifølge DIN EN 1717 skal gennmestrømningsbeg rænsere i overenstemmelse med nationale regler afprøves regelmæssigt mindst en gang om året Reservedele se s 3 1 Greb 16597XXX 2 Dækknap til greb koldt varmvandsside 97987000 3 Bøsning 97993XXX 4 Perlator kpl M24x1 98575XXX 5 Afspærringsventil 94009000 6 Kontraventil 94074000 7 Omsti...

Page 12: ...o ou hidráu lico desde que a pressão de utilização seja no minimo de 0 15 MPa Atenção As válvulas anti retorno devem ser verificadas re gularmente de acordo com a DIN EN 1717 segun do os regulamentos nacionais ou regionais pelo menos uma vez por ano Peças de substituição ver página 3 1 Manípulo 16597XXX 2 Tampa de parafuso de água fria quente 97987000 3 Cápsula 97993XXX 4 Emulsor compl M24x1 98575...

Page 13: ...zypadku gdy ciśnienie przepływu wynosi co najmniej 0 15 MPa Uwaga Zawory zwrotne muszą być według normy DIN EN 1717 na regionalnych warunkach kontrolo wane przynajmniej raz w roku Części serwisowe zobacz str 3 1 Uchwyt 16597XXX 2 Korek maskujący woda zimna i ciepła 97987000 3 Tuleja 97993XXX 4 Napowietrzacz perlator M24x1 98575XXX 5 Zespół odcinający po stronie 94009000 6 Zabezpieczenie przepływu ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...16 Hansgrohe Postfach 1145 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 02 2009 9 05821 01 ...

Reviews: