0 2
A S S E M B L Y (see page 04 )
EN
S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
⁄ The drain valve must only be used as intended. It is not
allowed to attach other objects to the drain valve, for
example a semi-pedestal.
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 06 )
To adjust the hot water limiter. Using a hot water
limiter in combination with a continuous flow
water heater is not recommended.
D I M E N S I O N S (see page 08 )
F L O W D I A G R A M
(see page 08 )
S P A R E P A R T S (see page 10 )
S P E C I A L A C C E S S O R I E S
(order as an extra)
⁄ special tool #58085000 (see page 04 )
⁄ Installation putty (see page 05)
C L E A N I N G (see page 07)
O P E R A T I O N (see page 12 )
Hansgrohe recommends not to use as drinking water the
first half liter of water drawn in the morning or after a
prolonged period of non-use.
F A U L T
C A U S E
R E M E D Y
⁄ Insufficient water
⁄ Aerator calcified, dirty
⁄ Clean aerator, replace as necessary
⁄ Mixer stiff
⁄ Cartridge defective
⁄ Exchange cartridge
⁄ Mixer dripping
⁄ Cartridge defective
⁄ Exchange cartridge
⁄ Water escaping at the connection
hose
⁄ Cartridge defective
⁄ Exchange cartridge
⁄ O-ring defective
⁄ Exchange O-ring
⁄ Water escaping at the connection
hose
⁄ Connection hose defective
⁄ Exchange connection hose
⁄ O-ring defective
⁄ Exchange O-ring
⁄ Adapter for cartridge defective
⁄ Exchange adapteur pour cartouche
⁄ O ring of adapter for cartridge defec-
tive
⁄ Exchange O-ring
⁄ Hot water temperature too low
⁄ Hot water limiter incorrectly set
⁄ Set hot water limiter