SafetyNotes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The shower system may only be used for bathing, hygienic and body cleansing
purposes.
The hot and cold supplies must be of equal pressures.
The product may not be used as a holding handle. A separate handle must be
installed.
Children as well as adults with physical, mental and/or sensoric impairments
must not use this shower system without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this shower system.
InstallationInstructions
• The fitting must be installed, flushed and tested after the valid norms!
• The plumbing codes applicable in the respective countries must be oberserved.
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• Where the contractor mounts the product, he should ensure that the entire area of
the wall to which the mounting plate is to be fitted, is flat (no projecting joints or
tiles sticking out), that the structure of the wall is suitable for the installation of the
product and has no weak points. The enclosed screws and dowels are only suit-
able for concrete. For another wall constructions the manufacturer's indications of
the dowel manufacturer have to be taken into account.
• The mesh washer must be insert to protect the overhead shower against incoming
dirt by pipework. Incoming dirt leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and guarantee claims.
TechnicalData
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
Hansgrohe mixers can be used together with hydraulically and thermically con-
trolled continuous flow heaters if the flow pressure is at least 0,15 MPa.
Safety against backflow
The product is exclusively designed for drinking water!
English
Operation
(see page 40)
Maintenance
(see page 37)
• The check valves must be checked regularly according to DIN EN
1717 in accordance with national or regional regulations (at least
once a year).
• To guarantee the smooth running of the thermostat, it is necessary
from time to time to turn the thermostat from total hot to total cold.
Spareparts
(see page 38)
Assemblyseepage31
Dimensions
(see page 34)
Do not use silicone containing acetic acid!
Adjustment
(see page 36)
After the installation, the output temperature of the fitting must be tested
and set to the temperate desired by the customer.
Symboldescription
Flowdiagram
(see page 34)
Tub outlet
Shower outlet
Cleaning
(see page 37) and enclosed brochure
SafetyFunction
(see page 36)
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
4