3
3 (16)
Assembly
(See Page 6)
Troubleshooting
Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Filters are dirty (97367000)
- Clean filter in front of the mixer
and on the MTC-thermo cartridge
(97367000)
- Shower filter seal dirty
- Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
- Backflow preventers dirty or
leaking
- Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
- Thermostat has not been adjusted - Adjust thermostat
- Hot water temperature too low
- Increase hot water temperature to
42 ºC to 60 ºC
Temperature regulation not possible - thermo cartridge calcified
- Exchange thermo cartridge
Shower or spout dripping
- Dirt or sedimentation on valve
seat, shut-off unit damaged
- Clean or exchange shut-off unit
English