22 (16)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The product is not designed to be used with steam
baths!
• The mixer must be installed, flushed and tested!
Assembly
(see page 6)
Pressure and permeability test
• The connections of the thermostatic mixer should be
tested regular after installation.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar ≈ 147 PSI)
Hot water temperature:
max. 60°C
Centre distance:
160 mm
Connections M 26x1,5:
cold right - hot left
Thermal disinfection:
70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking
water!
Symbol description
Do not use silicone containing acetic acid!
Safety Function
(see page 8)
The desired maximum temperature for example max.
42º C can be pre-set thanks to the safety function.
Adjustment
(see page 7)
After the installation, the output temperature of the
thermostat must be checked. A correction is necessary if
the temperature measured at the output differs from the
temperature set on the thermostat.
Maintenance
(see page 9)
To guarantee the smooth running of the thermostat, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
The mixer is equipped with non return valves. The
non return valves must be checked regularly
according to EN 806-5 in accordance with national
or regional regulations (at least once a year).
Operation
(see page 11)
Dimensions
(see page 13)
Flow diagram
(see page 13)
Shower
Bath tub
Spare parts
(see page 14)
Test certificate
(see page 16)
Cleaning
(see page 15)
English