background image

4

English

Assembly 

(see page 32)

 

Safety Notes

 

Gloves should be worn during installation to prevent crushing and cutting 
injuries.

 

The arm of the shower head is intended only to hold the shower head. Do not 
load it down with other objects!

 

Children as well as adults with physical, mental and/or sensoric impairments 
must not use this product without proper supervision. Persons under the 
influence of alcohol or drugs are prohibited from using this product.

 

Do not allow the streams of the shower touch sensitive body parts (such as your 
eyes). An adequate distance must be kept between the shower and you.

 

The product may not be used as a holding handle. A separate handle must be 
installed.

 

The product may only be used for bathing, hygienic and body cleaning 
purposes.

 

The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport damages. After it has been 

installed, no transport or surface damage will be honoured.

• The pipes and the fixture must be installed, flushed and tested as per the 

applicable standards.

• The plumbing codes applicable in the respective countries must be observed.
• The installation dimensions stated in these installation instructions are ideal for 

people of approximately 1800 mm in body height. The dimensions can be 
altered if required. In this case, pay attention to the fact that a change of 
installation height will also change the minimum height, and that the altered 
mounting dimensions must be taken into consideration.

• During installation of the product by qualified trained personnel, make sure that 

the entire fastening surface is even and smooth (no protruding seams or tile 
offset), that the finish of the wall is suitable to apply the product and has no 
weak points.

• The mesh washer must be insert to protect the shower against incoming dirt by 

pipework. Incoming dirt leads to defects or/and can damage parts of the 
shower; such caused faults voids all liability and guarantee claims.

• The product is not designed to be used with steam baths!
• If required, the bottom part of the pipe between the fixture and the shower head 

can be shortened with a fine-toothed saw.

• In case of problems with the continuous water heater or of greatly varying 

water pressures, you must install the water limiter (comprised in the delivery, 
article number 97510000) in the cold water supply.

Technical Data

Operating pressure: 

max. 1 MPa 

27268XXX Recommended operating pressure: 

0,1 - 0,5 MPa 

27281XXX / 26596000 Recommended operating pressure: 

0,13 - 0,5 MPa 

Test pressure: 

1,6 MPa 

 

(1 MPa = 10 bar = 147 PSI) 

Hot water temperature: 

max. 60°C 

Thermal disinfection: 

70°C / 4 min 

Centre distance: 

150±12 mm 

Connections G 1/2: 

cold right - hot left

• Safety against backflow
• The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!

Adjustment 

(see page 34)

To adjust the hot water limiter. Using a hot water limiter in combination with a 
continuous flow water heater is not recommended.

Safety Function 

(see page 41)

The desired maximum temperature for example max. 42º C can be pre-set thanks 
to the safety function.

Maintenance 

(see page 40)

• The check valves must be checked regularly according to EN 806-5 in 

accordance with national or regional regulations (at least once a year).

• To guarantee the smooth running of the thermostat, it is necessary from time to 

time to turn the thermostat from total hot to total cold.

Dimensions 

(see page 36)

Flow diagram 

(see page 36)

c

  Hand shower

d

  Overhead shower

Spare parts 

(see page 41)

Special accessories 

(order as an extra)

tile-matching-disk #95239000 (see page 41)

Cleaning 

(see page 38)

Operation 

(see page 35)

To empty the overhead shower after use, hold it in a slightly inclined position.

Test certificate 

(see page 41)

Fault

Cause

Remedy

Insufficient water

- Supply pressure inadequate

- Check water pressure (If a pump has been installed 

check to see if the pump is working).

- Regulator filter dirty

- Clean filter in front of the mixer and on the MTC-ther-

mo cartridge #96922000

- Shower filter seal dirty

- Clean filter seal between shower and hose

Crossflow, hot water being forced into cold water 
pipe, or vice versa, when mixer is closed

- Backflow preventers dirty or leaking

- Clean backflow preventers, exchange if necessary

Spout temperature does not correspond with 
temperature set

- Thermostat has not been adjusted

- Adjust thermostat

- Hot water temperature too low

- Increase hot water temperature to 42 ºC to 60 ºC

Temperature regulation not possible

- thermo cartridge calcified

- Exchange thermo cartridge

Instantaneous heater didn't work with thermostat

- Filters are dirty

- Clean the filter / exchange filter

- check valve hasn't moved back

- Exchange check valves

- Flow limiter in handshower isn’t removed

- Remove flow limiter

Summary of Contents for 26596000

Page 1: ...t ohje Asennusohje 15 SV Bruksanvisning Monteringsanvisning 16 LT Vartotojo instrukcija Montavimo instrukcijos 17 HR Upute za uporabu Uputstva za instalaciju 18 TR Kullan m k lavuzu Montaj k lavuzu 19...

Page 2: ...er oder gro en Druckunterschieden muss die beigepackte Drossel Artikelnummer 97510000 in den Kaltwasserzulauf eingesetzt werden Technische Daten Betriebsdruck max 1 MPa 27268XXX Empfohlener Betriebsdr...

Page 3: ...n tan ou bien lorsqu il y a une trop grosse di rence de pression Informations techniques Pression de service autoris e max 1 MPa 27268XXX Pression de service conseill e 0 1 0 5 MPa 27281XXX 26596000 P...

Page 4: ...stall the water limiter comprised in the delivery article number 97510000 in the cold water supply Technical Data Operating pressure max 1 MPa 27268XXX Recommended operating pressure 0 1 0 5 MPa 27281...

Page 5: ...andi di erenze di pressione bisogna inserire il limitatore di portata in dotazione codice articolo 97510000 nel tubo d entrata dell acqua fredda Dati tecnici Pressione d uso max 1 MPa 27268XXX Pressio...

Page 6: ...2 X 36 mm X 36 X Silicone 1 2 3a 3b 4 5 6 2 1 2 1 36 mm max 39 mm max 5 mm 7 8 9 3 2 2 11 10 12 SW 24 mm SW 30 mm 17 Nm 13 14 Armaturenfett Grease A r m a t u r e n f e t t G r e a s e 1 1 SW 4 mm 8 N...

Page 7: ...33 15 16 1 2 17 60 6 mm SW 3 mm 4 Nm 18 1 2 3 s i l i c o n e 20 97246000 2 1 19 SW 17 mm 10 Nm 97246000...

Page 8: ...34 1 3 4 2 5 6 SW 3 mm SW 3 mm 2 Nm 1 4 6 5 1 2 SW 3 mm z B 42 C for example 42 C 2 3 1 2 SW 3 mm 2 Nm...

Page 9: ...rzlo k lm auksts hladno kaldt i ftoht schlie en ferm close chiudere cerrar sluiten lukke fechar zamkn zav t uzavrie bez r s sulkeminen st nga u daryti Zatvaranje kapatmak nchide zapreti sulgege aizv r...

Page 10: ...0 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec Crometta S 240 1jet Showerpipe EcoSmart 27268XXX 2 4 2 22 240 82 43 150 12 295 6 8 G 1 2 240 468 352 62 6 0 1 0 0 10 3 4 1114 1...

Page 11: ...12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec 1 2 2 214 110 0 2 3 01 m i n 2 5 2 3 2 6 13 0 6 8 G 1 2 240 470 355 62 6 0 1 0 0 10 3 4 1114 100 12 01 15 15 78 max 281 43 4 2 22 82 43...

Page 12: ...inent par un simple passage de la main EN Just clean simply rub over the spray nozzles to remove lime scale IT Facile da pulire Il calcare viene eliminato semplicemente dagli ugelli elastici in silico...

Page 13: ...39 1 min 3 6 5 1 4 3 4 5 1 min SW 17 mm SW 17 mm 10 Nm 1 2 6 2...

Page 14: ...m 3 4 7 SW 30 mm 17 Nm 6 1 2 3 4 SW 3 mm 1 2 3 4 1 5 SW 3 mm 4 Nm 7 5 SW 10 mm 20 Nm rot rouge red rosso rojo rood R d vermelho czerwony erven piros punainen r d raudona crvena k rm z ro u rde a punan...

Page 15: ...6157XXX SW 30 mm 98137000 17x1 5 94246000 94246000 94246000 93072XXX 95659000 9 l min 26727XXX 95659000 9 l min 95659000 9 l min 95239XXX P IX DVGW SINTEF NF ETA 27268XXX X X 27281XXX X X 26596000 X X...

Page 16: ...42...

Page 17: ...43...

Page 18: ...44...

Page 19: ...45...

Page 20: ...46...

Page 21: ...47...

Page 22: ...Hansgrohe Auestra e 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 05 2021 9 01489 06...

Reviews: