6
English
Assembly
1. Flush through the supply pipes.
2. Mount the S - unions and align them.
3. Fasten the mixer with the washers.
Large differences in pressure between the hot and
cold water supply should be balanced.
Operation
The mixer is actuated by lifting the lever head.
Swivel to the left = hot water,
swivel to the right = cold water.
14460000: The flow is changed from bath to
shower function by pulling the knop at the upper
side of the spout. After shutting off the water flow,
the mixer returns automatically to the bath function.
Technical Data
Operating pressure:
max. 10 bars
Recommended operating pressure:
1 - 5 bars
Test pressure:
16 bars
Hot water temperature:
max. 80° C
Recommended hot water temp.:
65° C
Centre distance:
150 ± 16 mm
Connections G ½":
cold right - hot left
Rate of flow 3 bares:
approx. 22 l/min
anti-pollution function
To adjust the hot water limiter on single lever mixers,
please see page 13.
No adjustment is necessary when using a
continuous flow water heater.
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 1.5 bars.
Spare parts
1
handle
96602000
1.1 screw cover
96338000
2
flange
94192000
3
nut
94194000
4
cartridge cpl.
92730000
5
escutcheon
94135000
6
S - unions
94140000
7
aerator cpl.
13956000
8
selector
94077000
9
diverter knob
94078000
10
non return valve
94074000
Fault
Cause
Rem edy
Insufficient water
-
-
-
Shower filter seal dirty
Aerator dirty
Non return ralve didn’t move
back
-
-
-
Clean filter seal between
shower and hose
Clean areator /exchange
aerator
Exchange non return valves
Mixer stiff
- Cartridge defective
- Exchange cartridge
Mixer dripping
- Cartridge defective
Sedimentation
- Exchange cartridge
Hot water temperature too low
- Hot water limiter incor-rectly set
- Set hot water limiter
Instantaneous heater didn’t
work
-
-
-
Flow limiter in handshower isn’t
removed
Aerator dirty
Non return ralve didn’t move
back
-
-
-
Remove flow limiter
Clean areator /exchange
aeratorr
Exchange non return valves