Hanna Instruments HI 9813-6 Instruction Manual Download Page 14

14

PROBES

HI 1285-5

Combination, amplified pH/EC/TDS/temperature probe
with built-in temperature sensor, 8-pin DIN connector
and 1 m (3.3') cable

HI 1285-6

Combination, amplified pH/EC/TDS/temperature probe
with Cal-Check feature, built-in temperature sensor,
8-pin DIN connector and 1 m (3.3') cable

pH BUFFER SOLUTIONS

HI 7004L

pH 4.01 buffer solution, 500 mL bottle

HI 7006L

pH 6.86 buffer solution, 500 mL bottle

HI 7007L

pH 7.01 buffer solution, 500 mL bottle

HI 7009L

pH 9.18 buffer solution, 500 mL bottle

HI 7010L

pH 10.01 buffer solution, 500 mL bottle

CONDUCTIVITY & TDS CALIBRATION SOLUTIONS

HI 7031L

1413 

μ

S/cm solution, 500 mL bottle

HI 7442L

1500 ppm (mg/L) solution, 500 mL bottle

OTHER SOLUTIONS

HI 700661P

Cleaning solution, 20 mL sachet (25 pcs)

HI 50021P

Check solution, 20 mL sachet (25 pcs)

HI 70300L

Storage solution, 500 mL bottle

HI 7073L

Protein cleaning solution, 500 mL bottle

HI 7074L

Inorganic cleaning solution, 500 mL bottle

HI 7077L

Oil & Fat cleaning solution, 500 mL bottle

OTHER ACCESSORIES

HI 710007

Shockproof rubber boot, blue

HI 710008

Shockproof rubber boot, orange

HI 710022

Blue protective case

ACCESSORIES

ACCESSORIES

ACCESSORIES

ACCESSORIES

ACCESSORIES

Summary of Contents for HI 9813-6

Page 1: ...1 Instruction Manual HI 9813 5 HI 9813 6 Portable pH EC TDS C Meters www hannainst com...

Page 2: ...BLE OF CONTENTS TABLE OF CONTENTS HI 9813 5 and HI 9813 6 are guaranteed for two years against defects in workmanship and materials when used for their intended purpose and maintained according to ins...

Page 3: ...ake sure that no damage has occurred during shipment If noticeable damage is found notify your dealer Each meter is supplied with Combination probe with 8 pin DIN connector 1 m 3 3 cable HI 1285 5 pH...

Page 4: ...on key 5 ppm TDS selection key 6 pH offset calibration knob 7 EC TDS calibration knob 8 C Temperature selection key 9 On Off key FUNCTIONAL DESCRIPTION OF HI 9813 5 FUNCTIONAL DESCRIPTION OF HI 9813 5...

Page 5: ...pm TDS range selection key 6 pH offset calibration knob 7 EC TDS calibration knob 8 C Temperature selection key 9 Check key 10 On Off key FUNCTIONAL DESCRIPTION OF HI 9813 6 FUNCTIONAL DESCRIPTION OF...

Page 6: ...a r b i l a C S D T C E e p o l s h g u o r h t t n i o p 1 l a u n a M r e m m i r t e r u t a r e p m e T S D T C E n o i t a s n e p m o C F 2 2 1 o t 2 3 C 0 5 o t 0 m o r f c i t a m o t u A h t...

Page 7: ...simply submerge the tip 4cm 1 of the probe into the sample to be tested Select the pH mode Stir briefly and wait a couple of minutes for the reading to adjust and stabilize The display shows the pH v...

Page 8: ...S mode TAKING TEMPERATURE MEASUREMENTS Submerge the tip 4cm 1 of the probe into the sample to be tested Select the C mode Stir briefly and wait a couple of minutes for the reading to adjust and stabil...

Page 9: ...HI 7009 instead of pH 10 01 PROCEDURE Connect the probe and switch the meter on then press the pH key to display pH measurement Remove the protective cap from the probe rinse and immerse it in the bu...

Page 10: ...4 0 9 5 8 9 0 5 2 2 1 6 0 4 3 8 6 8 9 6 1 0 9 2 8 9 5 5 1 3 1 8 0 4 4 8 6 8 9 6 9 9 8 9 7 9 0 6 0 4 1 9 0 4 4 8 6 8 9 6 7 9 8 7 7 9 5 6 9 4 1 1 1 4 4 8 6 9 9 6 5 9 8 6 7 9 0 7 8 5 1 2 1 4 5 8 6 9 9 6...

Page 11: ...nductivity calibration solution e g HI 7031 into a beaker If possible use plastic beaker to minimize any EMC interference Immerse the probe in the solution Wait for a couple of minutes for thermal equ...

Page 12: ...dous area using a 9V alkaline battery Unscrew the three screws on the rear of the meter remove the battery compartment cover and replace the 9V battery with a new one while observing its polarity Make...

Page 13: ...be is broken and has to be replaced Press the Check key If the meter is calibrated Probe is OK message is displayed If cleaning is needed Clean Probe and Calibrate message is displayed 1 immerse the p...

Page 14: ...ion 500 mL bottle HI 7010L pH 10 01 buffer solution 500 mL bottle CONDUCTIVITY TDS CALIBRATION SOLUTIONS HI 7031L 1413 S cm solution 500 mL bottle HI 7442L 1500 ppm mg L solution 500 mL bottle OTHER S...

Page 15: ...follow all necessary steps to correct interferences The glass bulb at the end of the electrode is sensitive to electrostatic discharges Avoid touching this glass bulb at all times During operation ES...

Page 16: ...Hanna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA Technical Support for Customers Tel 800 426 6287 Fax 401 765 7575 E mail tech hannainst com www hannainst com...