Hanna Instruments HI 9810 Instruction Manual Download Page 10

19

18

CE DECLARATION OF CONFORMITY

CE DECLARATION OF CONFORMITY

CE DECLARATION OF CONFORMITY

CE DECLARATION OF CONFORMITY

CE DECLARATION OF CONFORMITY

Recommendations for Users

Before using these products, make sure that they are entirely suitable for the environment in which
they are used.
Operation of these instruments in residential areas could cause unacceptable interferences to radio and
TV equipment.
The metal band at the end of the electrode is sensitive to electrostatic discharges. Avoid touching this
metal band all the times.
The glass bulb at the end of the electrode is sensitive to electrostatic discharges. Avoid touching this
glass bulb at all times.
During operation, ESD wrist straps should be worn to avoid possible damage to the electrode by
electrostatic discharges.
Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC
performance.
To avoid electrical shock, do not use these instruments when voltages at the measurement surface
exceed 24VAC or 60VDC.
To avoid damages or burns, do not perform any measurement in microwave ovens.

WARRANTY

WARRANTY

WARRANTY

WARRANTY

WARRANTY

All Hanna Instruments

 meters are warranted for two years 

against

defects in workmanship and materials when used for their intended
purpose and maintained according to instructions. 

The electrodes and

the probes are warranted for a period of six months. 

This warranty

is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed
maintenance are not covered.
If service is required, contact the dealer from whom you purchased the
instrument. If under warranty, report the model number, date of
purchase, serial number and the nature of the failure. If the repair is not
covered by the warranty, you will be notified of the charges incurred. If
the instrument is to be returned to Hanna Instruments, first obtain a
Returned Goods Authorization number from the Customer Service depart-
ment and then send it with shipping costs prepaid. When shipping any
instrument, make sure it is properly packaged for complete protection.
To validate your warranty, fill out and return the enclosed warranty card
within 14 days from the date of purchase.

All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner,
Hanna Instruments Inc., 584 Park East Drive, Woonsocket, Rhode
Island, 02895 , USA.

Hanna Instruments reserves the right to modify the design, construc-
tion and appearance of its products without advance notice.

Summary of Contents for HI 9810

Page 1: ...Instruction Manual HI 9810 Portable pH EC TDS Meter h t t p w w w h a n n a i n s t c o m This Instrument is in Compliance with the CE Directives...

Page 2: ...rature and for this reason measurements are carried out with reference to a standard temperature of 25 C If the solution measured has a different tem perature than 25 C compensation must be performed...

Page 3: ...with a of 2 C Electrode HI 1285 combination pH EC TDS electrode with temperature sensor and 1 m 3 3 cable included Battery Type 9 Volt 150 hours of continuous use Environment 0to50 C 32to122 F max 95...

Page 4: ...N Each meter is supplied complete with a 9V battery Slide off the battery compartment cover on the back of the meter see page 16 install the battery while paying attention to its polarity Connect the...

Page 5: ...chemicals d Where extreme accuracy is required PREPARATION Pour small quantities of pH 7 01 HI 7007 or HI 8007 orpH4 01 HI 7004orHI 8004 or pH 10 01 HI 7010 or HI 8010 solution into a clean beaker To...

Page 6: ...gs are usually normalized at 25 C HI 9810 automatically compensates for temperature differences with a built in temperature sensor circuitry With this compensation the display shows the readings at 25...

Page 7: ...e electrode and recalibrate the meter to see if the problem is alleviated ELECTRODE CONDITIONING ELECTRODE CONDITIONING ELECTRODE CONDITIONING ELECTRODE CONDITIONING ELECTRODE CONDITIONING AND MAINTEN...

Page 8: ...1 Rugged carrying case ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES pH CALIBRATION SOLUTIONS HI 70004P pH 4 01 Buffer Sachets 25 x 20 mL HI 7004M pH 4 01 Buffer Solution 230 mL HI 7004L...

Page 9: ...EMICAL TEST KITS CHLORINE METERS CONDUCTIVITY TDS METERS DISSOLVED OXYGEN METERS HYGROMETERS ION SPECIFIC METERS Colorimeters MAGNETIC STIRRERS Na NaCl METERS pH ORP Na ELECTRODES PROBES DO S cm RH T...

Page 10: ...warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions The electrodes and the probes are warranted for a per...

Page 11: ...plications The reference literature currently covers areas such as Water Treatment Process Swimming Pools Agriculture Food Laboratory Thermometry and many others New reference material is constantly b...

Reviews: