DISPLAY FUNCTIONAL DESCRIPTION

1) Primary display
2) Secondary display

LOG

INTV

LO BAT

TIME

DATE

°C

1

2

For printing and measuring temperature in
the higher ranges without having to compro-
mise high resolution, HANNA instruments

®

has developed the HI 955201 single channel
and the HI 955202 dual channel, 4-wire Pt100
printing thermometers.
These thermometers have a resolution of 0.1°C
in the range of -200.0 to 850.0°C. A built-in
printer makes it possible to obtain a hard-
copy of your temperature measurements taken
on 1 or 2 channels, instantly or at determin-
able intervals. The low-power printer uses plain
paper that will not fade over time and is
widely available.
For extended time measurements, the meters
can be powered with 12 Vdc.
These meters are calibrated against certified
standards.
HI 955301 and HI 955302 combine the high
resolution and extended temperature range of
the  HI 955201 and HI 955202 models with
extensive logging capabilities and an infrared
data transfer system. In addition to supplying
the user with instant printouts of date, time
and temperature, they also provide data log-
ging facilities that store data for transfer to a
computer system for retrieval and/or printing
at a later date.
HI 955301 accepts one temperature probe
while HI 955302 can take 2 separate Pt100
probes.
The sophisticated software allocates up to
16000 temperature readings to maximize avail-
able space, regardless of the number of chan-
nels in use.
HANNA instruments

®

 offers a wide variety of

optional 4-wire Pt100 HI 768 temperature
probes to fit any application needs.

GENERAL DESCRIPTION

PRELIMINARY EXAMINATION

Remove the instrument from the packing mate-
rial and examine it carefully to make sure that no
damage has occurred during shipping. If there is
any damage, notify your dealer.

Each meter is supplied complete with:

5 paper rolls

Batteries (4 x 1.5V AA alkaline)

Rugged carrying case

Instruction manual

Note: Save all packing material until you are

sure that the instrument functions cor-
rectly. All defective items must be re-
turned in its original packaging together
with the supplied accessories.

Summary of Contents for HI 955202

Page 1: ...1 Instruction Manual HI 955201 HI 955202 HI 955301 HI 955302 1 or 2 Channel Printing and Logging Pt 100 Thermometers w w w h a n n a i n s t c o m...

Page 2: ...Declaration of Conformity 35 TABLE OF CONTENTS WARRANTY All Hanna Instruments meters are warranted for two years against defects in workmanship and materials when used for their intended purpose and m...

Page 3: ...apabilities and an infrared data transfer system In addition to supplying the user with instant printouts of date time and temperature they also provide data log ging facilities that store data for tr...

Page 4: ...de 3 4 5 6 7 8 9 10 11 2 1 C CH HI 955202 PT100 PRINTING THERMOMETER DUAL CHANNEL ON OFF INTV TEMP PAPER PRINT RECORD UP DOWN HI 955201 HI 955202 Range 200 0 to 850 0 C Resolution 0 1 C or 1 C selecta...

Page 5: ...e SPECIFICATIONS HI 955301 AND HI 955302 FUNCTIONAL DESCRIPTION HI 955301 AND HI 955302 HI 955301 HI 955302 Range 200 0 to 850 0 C Resolution 0 1 C or 1 C selectable Accuracy 0 1 C 0 1 of reading for...

Page 6: ...955201 and HI 955301 are provided with a single probe connection while HI 955202 and HI 955302 feature two probe connectors Looking at the display side channel 1 is the first connector on the top lef...

Page 7: ...d TIME keys to leave this mode TIME DATE UP TIME ALT TEMP TIME INTV TIME SETTING DATE TIME PRINTING INTERVAL for HI 955301 and HI 955302 only Turn the instrument on by pressing the TEMP key Press the...

Page 8: ...luggedin the meter will print only the value of the connected probe If the second probe is not connected during the re cording mode the data from the second probe will not be printed PRINT LOG INTV ON...

Page 9: ...will appear on the display next to the channel number not utilized and orrecorded When the meter is in record ing mode the LOG indica tion is displayed on the sec ondary display To save battery life...

Page 10: ...log d Printing interval indicator in minutes e Time HH MM f Temperature value s g Channel HI 955302 only UP DOWN TIME LOG ALT TEMP LOG LOG UP DOWN TIME LOG ALT TEMP LOG PRINT To continue logging with...

Page 11: ...ime and the LOG symbol will start blinking to indicate that data are now only stored into memory Notes It is recommended to use the external power adapter during logging with printing mode especially...

Page 12: ...LT TEMP INTV TIME INTV TIME LOG UP PAPER ALT PRINT Press the DOWN key to revert back to sam pling time and move back through samples To exit the recall mode press LOG Note This mode will not alter dat...

Page 13: ...ations on the secondary display mean that the meter has entered the log mode and has 15 pages of available memory remaining After the initial printout the time and printing logging in terval will reap...

Page 14: ...nd the transmitter Data transmission from the instrument to the PC is handled with the HI 92000 Windows compatible software by HANNA instruments HI 92000 offers a variety of features to help you in al...

Page 15: ...instrument through the 12 Vdc adapter and then proceed with battery replacement Only after new batteries have been installed the adapter can be un plugged without losing stored data HI 92000 allows yo...

Page 16: ...r caught under the cover and prevented printer fromadvancingpaperfeed Replacethebatterycoverandtightenthescrews 1 5V 1 5V 1 5V 1 5V SCREW POTS RESET PAPER PAPER PRINTER MAINTENANCE CHANGING THE INK CA...

Page 17: ...to have all ther mometers recalibrated at least once a year For an accurate annual recalibration contact the nearest HANNA Service Center 1 5V 1 5V 1 5V 1 5V SCREW POTS RESET CH C LOBAT The LO BAT in...

Page 18: ...instruments when voltages at the measurement surface exceed 24 Vac or 60 Vdc To avoid damages or burns do not perform any measure ment in microwave ovens 4 WIRE PT100 PROBES HI768A Air gas probe 1 m 3...

Page 19: ...03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 011 615 8582 Taiwan Tel 886 2...

Reviews: